Glove failure in elective thyroid surgery: A prospective randomized study.

Authors :
Timler D
Kusiński M
Iltchev P
Szarpak Ł
Śliwczyński A
Kuzdak K
Marczak M
Source :
International journal of occupational medicine and environmental health [Int J Occup Med Environ Health] 2015; Vol. 28 (3), pp. 499-505.
Publication Year :
2015

Abstract

Objectives: To analyze perforation rate in sterile gloves used by surgeons in the operating theatre of the Department of Endocrinological and General Surgery of Medical University of Lodz.<br />Material and Methods: Randomized and controlled trial. This study analyses the incidents of tears in sterile surgical gloves used by surgeons during operations on 3 types of thyroid diseases according to the 10th revision of International Statistical Classification of Diseases and Related Health Problems (ICD-10) codes. Nine hundred seventy-two pairs (sets) of gloves were collected from 321 surgical procedures. All gloves were tested immediately following surgery using the water leak test (EN455-1) to detect leakage.<br />Results: Glove perforation was detected in 89 of 972 glove sets (9.2%). Statistically relevant more often glove tears occurred in operator than the 1st assistant (p < 0.001). The sites of perforation were localized mostly on the middle finger of the non-dominant hand (22.5%), and the non-dominant ring finger (17.9%).<br />Conclusions: This study has proved that the role performed by the surgeon during the procedure (operator, 1st assistant) has significant influence on the risk of glove perforations. Nearly 90% of glove perforations are unnoticed during surgery.<br /> (This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.)

Details

Language :
English
ISSN :
1896-494X
Volume :
28
Issue :
3
Database :
MEDLINE
Journal :
International journal of occupational medicine and environmental health
Publication Type :
Academic Journal
Accession number :
26190726
Full Text :
https://doi.org/10.13075/ijomeh.1896.00428