Back to Search Start Over

A method for counting monosodium urate crystals in synovial fluid.

Authors :
Montagna P
Brizzolara R
Ferrone C
Cutolo M
Paolino S
Cimmino MA
Source :
Reumatismo [Reumatismo] 2015 Jun 30; Vol. 67 (1), pp. 29-32. Date of Electronic Publication: 2015 Jun 30.
Publication Year :
2015

Abstract

This study was aimed to standardize the technique for counting monosodium urate (MSU) crystals in the synovial fluid (SF) of patients with gout. A total of 52 SF specimens were examined under a polarized light microscope. The amount of SF ranged between 0.1 and 45 mL (median 3 mL). MSU crystals were counted in four areas with the same size at 400x magnification. Cytological examination of the same specimens was also performed. Median leukocyte count was 400 cells/mm3 (range 50-14,000 cells/mm3), with a median percentage of polymorphonuclear leukocytes of 9% (range 0%-98%). Median crystal count was 179.5 (range 3-1600). Inter- reader and intra-reader agreement in crystal counting were good with a weighed k of 0.89 [95% confidence interval (CI) 0.85-0.94] and 0.89 (95% CI 0.84-0.93), respectively. Our data indicate that the SF MSU crystal count is a feasible and highly reliable technique.

Details

Language :
English
ISSN :
0048-7449
Volume :
67
Issue :
1
Database :
MEDLINE
Journal :
Reumatismo
Publication Type :
Academic Journal
Accession number :
26150273
Full Text :