Back to Search Start Over

Accuracy of the surgeon's eye: use of the tip-apex distance in clinical practice.

Authors :
Wright J
Kahane S
Moeed A
MacDowell A
Source :
Injury [Injury] 2015 Jul; Vol. 46 (7), pp. 1346-8. Date of Electronic Publication: 2015 May 08.
Publication Year :
2015

Abstract

Tip-apex distance is a well described method for assessment of screw placement in dynamic hip screw fixation of proximal femoral fracture. A distance of <25mm is associated with a significantly lower rate of cut out of the fixation device. Measurement is frequently performed retrospectively, although there has been no demonstration as to what accuracy the surgeon has of estimating tip-apex distance from image intensifier images, whilst scrubbed in theatre. Thirty-one clinicians working within orthopaedic departments were tested in their ability to identify adequacy of tip-apex distance on a series of image intensifier images. Level of seniority, awareness of the concept of tip-apex distance and use of the concept in clinical practice were each assessed. The accuracy in identifying the correct TAD was 82.5% in consultants, 83.8% in registrars and 71.1% in Senior house officers (SHO). The method was used in clinical practice by 50% of consultants, 89% of registrars and none of the SHOs.<br /> (Copyright © 2015 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1879-0267
Volume :
46
Issue :
7
Database :
MEDLINE
Journal :
Injury
Publication Type :
Academic Journal
Accession number :
25986671
Full Text :
https://doi.org/10.1016/j.injury.2015.04.041