Back to Search
Start Over
Acute toxicity after image-guided intensity modulated radiation therapy compared to 3D conformal radiation therapy in prostate cancer patients.
- Source :
-
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2015 Mar 15; Vol. 91 (4), pp. 737-44. - Publication Year :
- 2015
-
Abstract
- Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows significant dose reductions to organs at risk in prostate cancer patients. However, clinical data identifying the benefits of IG-IMRT in daily practice are scarce. The purpose of this study was to compare dose distributions to organs at risk and acute gastrointestinal (GI) and genitourinary (GU) toxicity levels of patients treated to 78 Gy with either IG-IMRT or 3D-CRT.<br />Methods and Materials: Patients treated with 3D-CRT (n=215) and IG-IMRT (n=260) receiving 78 Gy in 39 fractions within 2 randomized trials were selected. Dose surface histograms of anorectum, anal canal, and bladder were calculated. Identical toxicity questionnaires were distributed at baseline, prior to fraction 20 and 30 and at 90 days after treatment. Radiation Therapy Oncology Group (RTOG) grade ≥1, ≥2, and ≥3 endpoints were derived directly from questionnaires. Univariate and multivariate binary logistic regression analyses were applied.<br />Results: The median volumes receiving 5 to 75 Gy were significantly lower (all P<.001) with IG-IMRT for anorectum, anal canal, and bladder. The mean dose to the anorectum was 34.4 Gy versus 47.3 Gy (P<.001), 23.6 Gy versus 44.6 Gy for the anal canal (P<.001), and 33.1 Gy versus 43.2 Gy for the bladder (P<.001). Significantly lower grade ≥2 toxicity was observed for proctitis, stool frequency ≥6/day, and urinary frequency ≥12/day. IG-IMRT resulted in significantly lower overall RTOG grade ≥2 GI toxicity (29% vs 49%, respectively, P=.002) and overall GU grade ≥2 toxicity (38% vs 48%, respectively, P=.009).<br />Conclusions: A clinically meaningful reduction in dose to organs at risk and acute toxicity levels was observed in IG-IMRT patients, as a result of improved technique and tighter margins. Therefore reduced late toxicity levels can be expected as well; additional research is needed to quantify such reductions.<br /> (Copyright © 2015 Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Gastrointestinal Tract radiation effects
Humans
Male
Radiotherapy Dosage
Radiotherapy, Conformal methods
Radiotherapy, Image-Guided methods
Radiotherapy, Intensity-Modulated methods
Urogenital System radiation effects
Anal Canal radiation effects
Organs at Risk radiation effects
Prostatic Neoplasms radiotherapy
Radiotherapy, Conformal adverse effects
Radiotherapy, Image-Guided adverse effects
Radiotherapy, Intensity-Modulated adverse effects
Rectum radiation effects
Urinary Bladder radiation effects
Subjects
Details
- Language :
- English
- ISSN :
- 1879-355X
- Volume :
- 91
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- International journal of radiation oncology, biology, physics
- Publication Type :
- Academic Journal
- Accession number :
- 25752386
- Full Text :
- https://doi.org/10.1016/j.ijrobp.2014.12.017