Back to Search Start Over

CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties Tomography.

Authors :
Balidemaj E
van den Berg CA
Trinks J
van Lier AL
Nederveen AJ
Stalpers LJ
Crezee H
Remis RF
Source :
IEEE transactions on medical imaging [IEEE Trans Med Imaging] 2015 Sep; Vol. 34 (9), pp. 1788-96. Date of Electronic Publication: 2015 Feb 20.
Publication Year :
2015

Abstract

Electric properties tomography (EPT) is an imaging modality to reconstruct the electric conductivity and permittivity inside the human body based on B1(+) maps acquired by a magnetic resonance imaging (MRI) system. Current implementations of EPT are based on the local Maxwell equations and assume piecewise constant media. The accuracy of the reconstructed maps may therefore be sensitive to noise and reconstruction errors occur near tissue boundaries. In this paper, we introduce a multiplicative regularized CSI-EPT method (contrast source inversion-electric properties tomography) where the electric tissue properties are retrieved in an iterative fashion based on a contrast source inversion approach. The method takes the integral representations for the electromagnetic field as a starting point and the tissue parameters are obtained by iteratively minimizing an objective function which measures the discrepancy between measured and modeled data and the discrepancy in satisfying a consistency equation known as the object equation. Furthermore, the objective function consists of a multiplicative Total Variation factor for noise suppression during the reconstruction process. Finally, the presented implementation is able to simultaneously include more than one B1(+) data set acquired by complementary RF excitation settings. We have performed in vivo simulations using a female pelvis model to compute the B1(+) fields. Three different RF excitation settings were used to acquire complementary B1(+) fields for an improved overall reconstruction. Numerical results illustrate the improved reconstruction near tissue boundaries and the ability of CSI-EPT to reconstruct small tissue structures.

Details

Language :
English
ISSN :
1558-254X
Volume :
34
Issue :
9
Database :
MEDLINE
Journal :
IEEE transactions on medical imaging
Publication Type :
Academic Journal
Accession number :
25706578
Full Text :
https://doi.org/10.1109/TMI.2015.2404944