Back to Search Start Over

Hematologic Effects of Heart Valve Prostheses and Vascular Grafts after Aortic Root Replacement.

Authors :
Monsefi N
Zierer A
Beiras-Fernandez A
Werner I
Weber CF
Wolf Z
Moritz A
Source :
The Thoracic and cardiovascular surgeon [Thorac Cardiovasc Surg] 2015 Sep; Vol. 63 (6), pp. 452-8. Date of Electronic Publication: 2015 Feb 17.
Publication Year :
2015

Abstract

Background: Heart valve prosthesis as well as vascular grafts cause changes in blood parameters. This may correlate with valve-related complications, less frequently observed after repair surgery. We thus studied changes in rheology after Bentall, Ross, or Tirone David (TD) procedure.<br />Methods: Seventeen patients underwent a TD, 17 patients underwent a Ross, and 16 patients underwent a Bentall procedure. Venous blood samples were collected 4 ± 3 (TD), 4 ± 3 (Ross), and 6 ± 3 years mean (Bentall) postoperatively. Concentrations of fibrinogen, leucocytes, platelets, haptoglobin, hemoglobin, lactate dehydrogenase (LDH), bilirubin, hematocrit, and β-thromboglobulin were determined. Platelet function and activity were analyzed. Results were compared with those of healthy control subjects.<br />Results: Level of fibrinogen was higher in the Bentall than in the other two groups (338 ± 63 vs. 298 ± 43 Ross and 308 ± 48 mg/dL TD, p > 0.05). LDH was also elevated in the Bentall group (311 ± 45 vs. 205 ± 30 Ross, p < 0.01 and 203 ± 34 U/l TD, p < 0.01). Platelet count and haptoglobin levels were significantly reduced in the Bentall (190 ± 43/nL, 2.4 ± 1 mg/dL) and TD groups (183 ± 52/nL, 89 ± 57 mg/dL) in comparison to the control group (250 ± 86/nL, 140 ± 53 mg/dL) with p < 0.05, whereas there were no significant differences in the Ross group (214 ± 47/nL and 129 ± 54 mg/dL) in comparison to the control group. Leucocyte count and platelet function showed no significant differences between the groups.<br />Conclusion: Polyester ascending aortic prostheses and more pronounced when combined with a prosthetic aortic valve cause hematologic changes compared with minimal deviations in Ross patients. We observed mild hemolysis, a decreased platelet count, and an increase in fibrinogen level in patients after conduit root replacement compared with procedures retaining an autologous aortic valve at midterm follow-up.<br /> (Georg Thieme Verlag KG Stuttgart · New York.)

Details

Language :
English
ISSN :
1439-1902
Volume :
63
Issue :
6
Database :
MEDLINE
Journal :
The Thoracic and cardiovascular surgeon
Publication Type :
Academic Journal
Accession number :
25703635
Full Text :
https://doi.org/10.1055/s-0035-1544183