Back to Search Start Over

Role of an electronic antimicrobial alert system in intensive care in dosing errors and pharmacist workload.

Authors :
Claus BO
Colpaert K
Steurbaut K
De Turck F
Vogelaers DP
Robays H
Decruyenaere J
Source :
International journal of clinical pharmacy [Int J Clin Pharm] 2015 Apr; Vol. 37 (2), pp. 387-94. Date of Electronic Publication: 2015 Feb 10.
Publication Year :
2015

Abstract

Background: Critically ill patients are vulnerable to dosing errors. We developed an electronic Antimicrobial Dose alert based upon Creatinine clearance (ADC-alert), which gives daily antimicrobial dosing advice based upon the 24-h creatinine clearance (CLcr).<br />Objective: Primary objective: to verify the correctness of the ADC-alert output and its benefit for the workload of the clinical pharmacist (CP). Secondary objective to compare the ADC-alert output between patients with normal and impaired CLcr.<br />Setting: The 36-bed surgical and medical intensive care unit (ICU) of the Ghent University Hospital, Ghent, Belgium.<br />Method: In a single centre prospective observational 44-day study, prescriptions were reviewed by CP and compared with the ADC-alert output advice. CP workload was calculated with and without the use of the ADC-alert. Impaired renal function was defined as a CLcr < 50 mL/min for at least 1 day during antimicrobial treatment in the ICU or the need for renal replacement therapy (RRT).<br />Main Outcome Measures: Correct dosing recommendation by ADC-alert compared to CP review and time spent by CP with and without the ADC-alert.<br />Results: A total of 87 patients (554 daily antimicrobial prescriptions; 435 patient days) were both screened by CP and ADC-alert. Renal function impairment occurred in 39 patients (44.8 %) with 12 patients requiring RRT. The ADC-alert gave a correct dosage advice in 483 prescriptions (87.2 %). The overall sensitivity was 77.3 %; specificity was 89.9 %. Use of the ADC-alert reduces CP workload with 76.5 % (average time spent per patient: 17 vs. 4 min). Patients with a CLcr < 50 mL/min less frequently received a correct recommendation than patients with normal CLcr (P = 0.001). This was due to configuration problems in dialysis patients.<br />Conclusion: We developed and evaluated an electronic alert system to generate dynamic antimicrobial dose adaptation based on the daily calculation of the 24-h CLcr of ICU patients. Its use led to substantial time savings for clinical pharmacists. However, the alert advice suffered from some developmental and other flaws. Despite resolving some of these shortcomings, bedside interpretation of the results and clinical judgement remain necessary.

Details

Language :
English
ISSN :
2210-7711
Volume :
37
Issue :
2
Database :
MEDLINE
Journal :
International journal of clinical pharmacy
Publication Type :
Academic Journal
Accession number :
25666942
Full Text :
https://doi.org/10.1007/s11096-015-0075-6