Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease.

Authors :
Stuijfzand WJ
Uusitalo V
Kero T
Danad I
Rijnierse MT
Saraste A
Raijmakers PG
Lammertsma AA
Harms HJ
Heymans MW
Huisman MC
Marques KM
Kajander SA
Pietilä M
Sörensen J
van Royen N
Knuuti J
Knaapen P
Source :
Circulation. Cardiovascular imaging [Circ Cardiovasc Imaging] 2015 Jan; Vol. 8 (1).
Publication Year :
2015

Abstract

Background: Quantitative myocardial perfusion imaging is increasingly used for the diagnosis of coronary artery disease. Quantitative perfusion imaging allows to noninvasively calculate fractional flow reserve (FFR). This so-called relative flow reserve (RFR) is defined as the ratio of hyperemic myocardial blood flow (MBF) in a stenotic area to hyperemic MBF in a normal perfused area. The aim of this study was to assess the value of RFR in the detection of significant coronary artery disease.<br />Methods and Results: From a clinical population of patients with suspected coronary artery disease who underwent oxygen-15-labeled water cardiac positron emission tomography and invasive coronary angiography, 92 patients with single- or 2-vessel disease were included. Intermediate lesions (diameter stenosis, 30%-90%; n=75) were interrogated by FFR. Thirty-eight (41%) vessels were deemed hemodynamically significant (>90% stenosis or FFR≤0.80). Hyperemic MBF, coronary flow reserve, and RFR were lower for vessels with a hemodynamically significant lesion (2.01±0.78 versus 2.90±1.16 mL·min(-1)·g(-1); P<0.001, 2.27±1.03 versus 3.10±1.29; P<0.001, and 0.67±0.23 versus 0.93±0.15; P<0.001, respectively). The correlation between RFR and FFR was moderate (r=0.54; P<0.01). Receiver operator characteristic curve analysis showed an area under the curve of 0.82 for RFR, which was not significantly higher compared with that for hyperemic MBF and coronary flow reserve (0.76; P=0.32 and 0.72; P=0.08, respectively).<br />Conclusions: Noninvasive estimation of FFR by quantitative perfusion positron emission tomography by calculating RFR is feasible, yet only a trend toward a slight improvement of diagnostic accuracy compared with hyperemic MBF assessment was determined.<br /> (© 2015 American Heart Association, Inc.)

Details

Language :
English
ISSN :
1942-0080
Volume :
8
Issue :
1
Database :
MEDLINE
Journal :
Circulation. Cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
25596142
Full Text :
https://doi.org/10.1161/CIRCIMAGING.114.002400