Back to Search
Start Over
A comparison of methods to detect postural transitions using a single tri-axial accelerometer.
- Source :
-
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2014; Vol. 2014, pp. 6234-7. - Publication Year :
- 2014
-
Abstract
- Two algorithms for evaluating postural transitions (PTs) in cohorts of 40 healthy younger and 40 older adults are described and evaluated. The time of sit-to-stand (SiSt) and stand-to-sit (StSi) transitions and their duration were measured with two tri-axial accelerometers, one on the chest and one on the lower back. Each algorithm was optimized for these sensor placements. The first algorithm for sensor placement on the chest used a scalar product and vertical velocity estimates. The second algorithm for sensor placement on the lower back used a vector magnitude and a discrete wavelet transform. Both algorithms performed excellently in PT classification for younger and older adults (>86%). However, the chest based sensor and algorithm were better for estimating transition duration (TD) with ICCs to video analysis ranging from 0.678 to 0.969.
Details
- Language :
- English
- ISSN :
- 2694-0604
- Volume :
- 2014
- Database :
- MEDLINE
- Journal :
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
- Publication Type :
- Academic Journal
- Accession number :
- 25571421
- Full Text :
- https://doi.org/10.1109/EMBC.2014.6945053