Back to Search
Start Over
Upgrade of MacCHESS facility for X-ray scattering of biological macromolecules in solution.
- Source :
-
Journal of synchrotron radiation [J Synchrotron Radiat] 2015 Jan; Vol. 22 (1), pp. 180-6. Date of Electronic Publication: 2015 Jan 01. - Publication Year :
- 2015
-
Abstract
- X-ray scattering of biological macromolecules in solution is an increasingly popular tool for structural biology and benefits greatly from modern high-brightness synchrotron sources. The upgraded MacCHESS BioSAXS station is now located at the 49-pole wiggler beamline G1. The 20-fold improved flux over the previous beamline F2 provides higher sample throughput and autonomous X-ray scattering data collection using a unique SAXS/WAXS dual detectors configuration. This setup achieves a combined q-range from 0.007 to 0.7 Å(-1), enabling better characterization of smaller molecules, while opening opportunities for emerging wide-angle scattering methods. In addition, a facility upgrade of the positron storage ring to continuous top-up mode has improved beam stability and eliminated beam drift over the course of typical BioSAXS experiments. Single exposure times have been reduced to 2 s for 3.560 mg ml(-1) lysozyme with an average quality factor I/σ of 20 in the Guinier region. A novel disposable plastic sample cell design that incorporates lower background X-ray window material provides users with a more pristine sample environment than previously available. Systematic comparisons of common X-ray window materials bonded to the cell have also been extended to the wide-angle regime, offering new insight into best choices for various q-space ranges. In addition, a quantitative assessment of signal-to-noise levels has been performed on the station to allow users to estimate necessary exposure times for obtaining usable signals in the Guinier regime. Users also have access to a new BioSAXS sample preparation laboratory which houses essential wet-chemistry equipment and biophysical instrumentation. User experiments at the upgraded BioSAXS station have been on-going since commissioning of the beamline in Summer 2013. A planned upgrade of the G1 insertion device to an undulator for the Winter 2014 cycle is expected to further improve flux by an order of magnitude.
- Subjects :
- Aldose-Ketose Isomerases chemistry
Animals
Computers
Cooperative Behavior
Equipment Design
Forms and Records Control
Muramidase chemistry
New York
Robotics
Software
Solutions
Specimen Handling
Temperature
X-Ray Diffraction methods
Molecular Structure
Scattering, Small Angle
Synchrotrons instrumentation
X-Ray Diffraction instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1600-5775
- Volume :
- 22
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of synchrotron radiation
- Publication Type :
- Academic Journal
- Accession number :
- 25537607
- Full Text :
- https://doi.org/10.1107/S1600577514020360