First-in-man analysis of the i-cor assist device in patients with cardiogenic shock.
- Source :
-
European heart journal. Acute cardiovascular care [Eur Heart J Acute Cardiovasc Care] 2015 Oct; Vol. 4 (5), pp. 475-81. Date of Electronic Publication: 2014 Dec 18. - Publication Year :
- 2015
-
Abstract
- Objective: In patients with refractory cardiogenic shock (CS) mechanical assistance by venous-arterial extracorporeal membrane oxygenation (VA-ECMO) therapy may be considered to reach haemodynamic stabilization. In this first-in-man study, we analysed the applicability of the new i-cor VA-ECMO assist device equipped with a diagonal pump system.<br />Methods and Results: In total, 15 patients with refractory CS were treated with the i-cor assist device in three tertiary care centres. In 71%, CS was due to acute myocardial infarction (AMI). At baseline, patients were hypotensive (systolic/diastolic blood pressure 97 ± 4/62 ± 4 mm Hg) despite high doses of catecholamines. Under ECMO therapy, a significant reduction in vasopressor therapy and serum lactate levels was observed (norepinephrine: 0.69 ± 0.1 µg/kg/min at baseline vs 0.21 ± 0.08 µg/kg/min on the last day of treatment, p<0.0001; serum lactate: 6.7 ± 1.4 mmol/l at baseline versus 1.3 ± 0.1 mmol/l on the last day, p<0.001). Inspiratory oxygen concentration was significantly reduced during the course of VA-ECMO support (80.4 ± 7.0% at baseline vs 42.7 ± 2.4% on final day; p<0.001). At baseline, three patients (20%) were on continuous haemodialysis treatment. Of the 12 patients without haemodialysis at baseline, only one patient required haemodialysis during the course of ECMO treatment. Glomerular filtration rate (GFR) significantly increased with treatment (41.2 ± 7.4 at baseline vs 69.0 ± 10.8 on last day; p=0.006). Bleeding at the insertion site was recorded in two patients (13.3%). Overall, 11 patients (73.3%) needed blood transfusion. Three patients (20%) developed signs of limb ischaemia that were fully reversible. Haemolysis was recorded in five patients (33%). None of the complications required the interruption of ECMO therapy. Overall mortality was 33.3% (five patients); two patients died during, and three patients after, ECMO therapy.<br />Conclusion: This first-in-man analysis suggests that the i-cor ECMO device is successfully applicable in humans. The data set the stage for further evaluation of this novel system and provide the necessary basis to design randomised evaluations.<br /> (© The European Society of Cardiology 2014.)
- Subjects :
- Blood Transfusion methods
Catecholamines metabolism
Extracorporeal Membrane Oxygenation adverse effects
Extracorporeal Membrane Oxygenation methods
Female
Germany epidemiology
Glomerular Filtration Rate drug effects
Hemodynamics drug effects
Hemodynamics physiology
Humans
Kidney Function Tests
Lactic Acid blood
Male
Middle Aged
Mortality
Myocardial Infarction pathology
Retrospective Studies
Shock, Cardiogenic pathology
Tertiary Care Centers
Extracorporeal Membrane Oxygenation instrumentation
Shock, Cardiogenic therapy
Subjects
Details
- Language :
- English
- ISSN :
- 2048-8734
- Volume :
- 4
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- European heart journal. Acute cardiovascular care
- Publication Type :
- Academic Journal
- Accession number :
- 25522745
- Full Text :
- https://doi.org/10.1177/2048872614561481