Back to Search
Start Over
Real world experience with an indigenously manufactured stent Cobal C--a retrospective study.
- Source :
-
Indian heart journal [Indian Heart J] 2014 Sep-Oct; Vol. 66 (5), pp. 525-9. Date of Electronic Publication: 2014 Sep 18. - Publication Year :
- 2014
-
Abstract
- Background: Second generation bare metal stents made of cobalt chromium alloy are superior to first generation stain less steel stents. The thin struts are shown to reduce clinical and angiographic adverse outcomes.<br />Objective: To study the long term clinical and angiographic outcomes in patients who underwent coronary angioplasty with an indigenously made cobalt chromium bare metal stents with thin strut Cobal+C™ (Relisys).<br />Methods: A total of 268 consecutive patients who underwent coronary angioplasty with Cobal+C stents were studied retrospectively. Clinical follow up was done after a minimum period of nine months through telephonic interview and angiographic follow up was done in 80 patients chosen randomly. The end points analyzed included major adverse cardiac events (MACE) at nine months and the rate of binary restenosis at follow up angiogram done between 9 and 15 months post angioplasty.<br />Results: Thirty four percent were diabetic and 33% had acute myocardial infarction. Females constituted 17%. Mean stent diameter was 2.88 ± 0.28 and mean stent length 18.8 ± 4.2. MACE at nine months was 4.5% with TLR 0.3%. The rate of binary restenosis was 21%. Patients with longer stent lengths and non-compliance with medications had significantly higher rates of binary restenosis.<br />Conclusions: The use of Relisys Cobal+C stents was associated with good long term clinical and angiographic outcomes as evidenced by low incidence of MACE and binary restenosis rates for a bare metal stent.<br /> (Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.)
- Subjects :
- Adult
Aged
Aged, 80 and over
Angioplasty, Balloon, Coronary
Chromium
Cobalt
Coronary Angiography
Coronary Restenosis epidemiology
Female
Follow-Up Studies
Humans
India epidemiology
Male
Middle Aged
Percutaneous Coronary Intervention
Retrospective Studies
Treatment Outcome
Coronary Disease surgery
Prosthesis Design
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 2213-3763
- Volume :
- 66
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Indian heart journal
- Publication Type :
- Academic Journal
- Accession number :
- 25443606
- Full Text :
- https://doi.org/10.1016/j.ihj.2014.08.015