Back to Search Start Over

Downsizing annuloplasty in ischemic mitral regurgitation: double row overlapping suture to avoid ring disinsertion in valve repair.

Authors :
Nappi F
Spadaccio C
Al-Attar N
Chello M
Lusini M
Barbato R
Acar C
Source :
Surgical technology international [Surg Technol Int] 2014 Nov; Vol. 25, pp. 203-6.
Publication Year :
2014

Abstract

The long-term outcomes of undersizing annuloplasty for the treatment of ischemic mitral regurgitation (IMR) is affected by the progressive dilation of the annulus, which carries increased risk for ring disinsertion. Reasons underlying this phenomenon might be found in the excess of physical stress on the annuloplasty sutures during the ventricular remodeling process. We report a technique based on the placement of a double row of overlapping sutures aiming at reducing the potential for ring disinsertion. Eleven patients with IMR undergoing mitral valve repair associated with coronary bypass grafting were treated with this technique and echocardiographically followed up at 6 and 12 months. The overall annular dimension decreased significantly with a significant reduction of the tenting area and no recurrence of mitral regurgitation at 1 year. A double row of overlapping sutures allowed firm attachment of the prosthetic ring while downsizing the annulus in IMR, limiting the consequences of changes in subannular ventricular geometry. This technique might therefore be considered a useful aid during mitral valve repair.

Details

Language :
English
ISSN :
1090-3941
Volume :
25
Database :
MEDLINE
Journal :
Surgical technology international
Publication Type :
Academic Journal
Accession number :
25433266