Back to Search Start Over

Quality Control and Reproducibility in M-Mode, Two-Dimensional, and Speckle Tracking Echocardiography Acquisition and Analysis: The CARDIA Study, Year 25 Examination Experience.

Authors :
Armstrong AC
Ricketts EP
Cox C
Adler P
Arynchyn A
Liu K
Stengel E
Sidney S
Lewis CE
Schreiner PJ
Shikany JM
Keck K
Merlo J
Gidding SS
Lima JA
Source :
Echocardiography (Mount Kisco, N.Y.) [Echocardiography] 2015 Aug; Vol. 32 (8), pp. 1233-40. Date of Electronic Publication: 2014 Nov 09.
Publication Year :
2015

Abstract

Introduction: Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy.<br />Methods: The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots.<br />Results: For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains.<br />Conclusion: Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies.<br /> (© 2014, Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1540-8175
Volume :
32
Issue :
8
Database :
MEDLINE
Journal :
Echocardiography (Mount Kisco, N.Y.)
Publication Type :
Academic Journal
Accession number :
25382818
Full Text :
https://doi.org/10.1111/echo.12832