Back to Search
Start Over
A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.
- Source :
-
Heart and vessels [Heart Vessels] 2016 Jan; Vol. 31 (1), pp. 38-45. Date of Electronic Publication: 2014 Sep 13. - Publication Year :
- 2016
-
Abstract
- Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)TlCl/(123)I-BMIPP dual-isotope imaging, the use of (99m)Tc-MIBI instead of (201)TlCl improves image quality as well as lowers radiation exposure.
- Subjects :
- Adult
Aged
Aged, 80 and over
Coronary Angiography methods
Feasibility Studies
Female
Heart physiopathology
Humans
Iofetamine administration & dosage
Japan
Male
Middle Aged
Myocardial Infarction surgery
Percutaneous Coronary Intervention methods
Phantoms, Imaging
Technetium Tc 99m Sestamibi administration & dosage
Fatty Acids metabolism
Myocardial Infarction diagnostic imaging
Myocardial Perfusion Imaging methods
Radiopharmaceuticals administration & dosage
Tomography, Emission-Computed, Single-Photon
Subjects
Details
- Language :
- English
- ISSN :
- 1615-2573
- Volume :
- 31
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Heart and vessels
- Publication Type :
- Academic Journal
- Accession number :
- 25217037
- Full Text :
- https://doi.org/10.1007/s00380-014-0578-4