Back to Search
Start Over
Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.
- Source :
-
American journal of kidney diseases : the official journal of the National Kidney Foundation [Am J Kidney Dis] 2014 Dec; Vol. 64 (6), pp. 918-36. Date of Electronic Publication: 2014 Aug 08. - Publication Year :
- 2014
-
Abstract
- Background: The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain.<br />Study Design: A systematic review of randomized trials and observational studies (case reports, case series, studies without a control group, non-English studies, and abstracts were excluded).<br />Setting & Population: HD patients (both in-center conventional HD and home HD) using an AVF for vascular access.<br />Selection Criteria for Studies: We searched MEDLINE, EMBASE, EBM Reviews, and CINAHL from the earliest date in the databases to March 2014 for studies comparing clinical outcomes of the buttonhole versus rope-ladder technique.<br />Intervention: Buttonhole versus rope-ladder cannulation technique.<br />Outcomes: The primary outcomes of interest were patient-reported cannulation pain and rates of AVF-related local and systemic infections. Secondary outcomes included access survival, intervention, hospitalization, and mortality, as well as hematoma and aneurysm formation, time to hemostasis, and all-cause hospitalization and mortality.<br />Results: Of 1,044 identified citations, 23 studies were selected for inclusion. There was equivocal evidence with respect to cannulation pain: pooled observational studies yielded a statistical reduction in pain with buttonhole cannulation (standardized mean difference, -0.76 [95%CI, -1.38 to -0.15] standard deviations), but no difference in cannulation pain was found among randomized controlled trials (standardized mean difference, 0.34 [95%CI, -0.76 to 1.43] standard deviations). Buttonhole, as compared to rope-ladder, technique appeared to be associated with increased risk of local and systemic infections.<br />Limitations: Overall poor quality and substantial heterogeneity among studies precluded pooling of most outcomes.<br />Conclusions: Evidence does not support the preferential use of buttonhole over rope-ladder cannulation in either facility-based conventional HD or home HD. This does not preclude buttonhole cannulation as being appropriate for some patients with difficult-to-access AVFs.<br /> (Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Arteriovenous Fistula epidemiology
Catheter-Related Infections epidemiology
Catheter-Related Infections prevention & control
Catheterization instrumentation
Humans
Kidney Failure, Chronic epidemiology
Observational Studies as Topic methods
Randomized Controlled Trials as Topic methods
Arteriovenous Fistula therapy
Catheterization methods
Kidney Failure, Chronic therapy
Renal Dialysis methods
Subjects
Details
- Language :
- English
- ISSN :
- 1523-6838
- Volume :
- 64
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- American journal of kidney diseases : the official journal of the National Kidney Foundation
- Publication Type :
- Academic Journal
- Accession number :
- 25110302
- Full Text :
- https://doi.org/10.1053/j.ajkd.2014.06.018