Back to Search
Start Over
High degree of accuracy of a novel image-free handheld robot for unicondylar knee arthroplasty in a cadaveric study.
- Source :
-
Clinical orthopaedics and related research [Clin Orthop Relat Res] 2015 Jan; Vol. 473 (1), pp. 206-12. - Publication Year :
- 2015
-
Abstract
- Background: Surgical robotics has been shown to improve the accuracy of bone preparation and soft tissue balance in unicondylar knee arthroplasty (UKA). However, although extensive data have emerged with regard to a CT scan-based haptically constrained robotic arm, little is known about the accuracy of a newer alternative, an imageless robotic system.<br />Questions/purposes: We assessed the accuracy of a novel imageless semiautonomous freehand robotic sculpting system in performing bone resection and preparation in UKA using cadaveric specimens.<br />Methods: In this controlled study, we compared the planned and final implant placement in 25 cadaveric specimens undergoing UKA using the new tool. A quantitative analysis was performed to determine the translational, angular, and rotational differences between the planned and achieved positions of the implants.<br />Results: The femoral implant rotational mean error was 1.04° to 1.88° and mean translational error was 0.72 to 1.29 mm across the three planes. The tibial implant rotational mean error was 1.48° to 1.98° and the mean translational error was 0.79 to 1.27 mm across the three planes.<br />Conclusions: The image-free robotic sculpting tool achieved accurate implementation of the surgical plan with small errors in implant placement. The next step will be to determine whether accurate implant placement translates into a clinical and functional benefit for the patient.
- Subjects :
- Anatomic Landmarks
Arthroplasty, Replacement, Knee methods
Biomechanical Phenomena
Cadaver
Equipment Design
Femur anatomy & histology
Femur physiology
Humans
Knee Joint anatomy & histology
Knee Joint physiology
Knee Prosthesis
Materials Testing
Surgery, Computer-Assisted methods
Tibia anatomy & histology
Tibia physiology
Arthroplasty, Replacement, Knee instrumentation
Femur surgery
Knee Joint surgery
Robotics instrumentation
Surgery, Computer-Assisted instrumentation
Tibia surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1528-1132
- Volume :
- 473
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Clinical orthopaedics and related research
- Publication Type :
- Academic Journal
- Accession number :
- 25002214
- Full Text :
- https://doi.org/10.1007/s11999-014-3764-x