Back to Search
Start Over
Comparison between drug screening by immunoassay and ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry in post-mortem urine.
- Source :
-
Drug testing and analysis [Drug Test Anal] 2015 May; Vol. 7 (5), pp. 420-7. Date of Electronic Publication: 2014 Jun 20. - Publication Year :
- 2015
-
Abstract
- Immunoassay is currently the most common approach for urine drug screening. However, the continuous emergence of new psychoactive substances (NPS) and their low urinary concentrations have challenged the scope and sensitivity of immunoassays. Consequently, specialized toxicology laboratories rely more and more on mass spectrometry (MS) based techniques. Ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOF-MS) is an especially attractive technique for comprehensive drug screening. The objective was to compare the performances of immunoassay and UHPLC-HR-TOF-MS in terms of scope, flexibility, sensitivity, and reliability of substance identification. A total of 279 post-mortem urine samples were analyzed using a method representative of each technique. The immunoassay method was an Emit II Plus enzyme immunoassay for the following drug groups: amphetamines, benzodiazepines, buprenorphine, cannabis, and opiates. The UHPLC-HR-TOF-MS method was a recently published method covering hundreds of drugs: conventional drugs of abuse, abused prescription drugs, and NPS of various classes. UHPLC-HR-TOF-MS produced a lower number of false positive (FP) results for the drug groups covered by immunoassay. Many of the false negative (FN, n = 40) and FP (n = 22) immunoassay results were obviously due to the higher cut-off concentrations and interfering matrix, respectively. Moreover, the wider scope of UHPLC-HR-TOF-MS allowed detection of NPS and prescription drugs. UHPLC-HR-TOF-MS gave FP results related to a few particular substances. The future option of adjusting all compound-specific reporting parameters individually would allow the method's sensitivity and specificity to be fully exploited.<br /> (Copyright © 2014 John Wiley & Sons, Ltd.)
- Subjects :
- Amphetamines urine
Analgesics, Opioid urine
Benzodiazepines urine
Buprenorphine urine
Cholic Acids urine
Chromatography, High Pressure Liquid
Humans
Immunoassay
Mass Spectrometry
Reproducibility of Results
Sensitivity and Specificity
Autopsy
Substance Abuse Detection methods
Urinalysis methods
Subjects
Details
- Language :
- English
- ISSN :
- 1942-7611
- Volume :
- 7
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Drug testing and analysis
- Publication Type :
- Academic Journal
- Accession number :
- 24953563
- Full Text :
- https://doi.org/10.1002/dta.1683