Back to Search Start Over

A soft-surgery approach to minimize hearing damage caused by the insertion of a cochlear implant electrode: a guinea pig animal model.

Authors :
Giordano P
Hatzopoulos S
Giarbini N
Prosser S
Petruccelli J
Simoni E
Faccioli C
Astolfi L
Martini A
Source :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology [Otol Neurotol] 2014 Sep; Vol. 35 (8), pp. 1440-5.
Publication Year :
2014

Abstract

Objective: A "soft surgery" technique was applied, using various types of specifically designed dummy electrodes, to mimic cochlear implantation in a guinea pig model, and the degree of hearing-preservation/cochlear damage was assessed.<br />Methods: Tricolor guinea pigs were divided into 3 groups: group A were implanted with electrodes without any contacts or wires (soft electrode), group B were implanted with electrodes having a metallic wire inside (stiff electrode), and group C underwent a cochleostomy procedure without implantation. Compound action potentials, in the range of 4 to 32 kHz, were used to assess electrophysiologic changes in the hearing function presurgery and postsurgery. Data were collected before surgery, at times t = 0 (immediately after surgery) and at 3, 7, 14, and 30 days.<br />Results: At low frequencies (4-8 kHz), an immediate elevation of hearing threshold was observed in all 3 groups. Higher threshold shifts were more consistent for group B implanted with a stiff electrode, in comparison to the other 2 groups. Animals from group C presented a recovery from hearing loss, starting 3 days after surgery. At high frequencies (16-32 kHz), the elevation of hearing threshold was higher, as compared with the data from the low frequencies. Group C animals presented oscillatory threshold shifts twice, and the recovery to normal threshold values occurred approximately at t = 14 days.<br />Conclusion: The data suggest that cochleostomy is minimally harmful to the inner ear and that a soft electrode might better preserve the inner ear integrity than a rigid electrode.

Details

Language :
English
ISSN :
1537-4505
Volume :
35
Issue :
8
Database :
MEDLINE
Journal :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Publication Type :
Academic Journal
Accession number :
24853240
Full Text :
https://doi.org/10.1097/MAO.0000000000000440