Back to Search
Start Over
3,4-Methylenedioxypyrovalerone (MDPV) and metabolites quantification in human and rat plasma by liquid chromatography-high resolution mass spectrometry.
- Source :
-
Analytica chimica acta [Anal Chim Acta] 2014 May 27; Vol. 827, pp. 54-63. Date of Electronic Publication: 2014 Apr 12. - Publication Year :
- 2014
-
Abstract
- Synthetic cathinones are recreational drugs that mimic the effects of illicit stimulants like cocaine, amphetamine or Ecstasy. Among the available synthetic cathinones in the United States, 3,4-methylenedioxypyrovalerone (MDPV) is commonly abused and associated with dangerous side effects. MDPV is a dopamine transporter blocker 10-fold more potent than cocaine as a locomotor stimulant in rats. Previous in vitro and in vivo studies examining MDPV metabolism reported 3,4-dihydroxypyrovalerone (3,4-catechol-PV) and 4-hydroxy-3-methoxypyrovalerone (4-OH-3-MeO-PV) as the two primary metabolites. We developed and validated a liquid chromatography-high resolution mass spectrometry method to quantify MDPV and its primary metabolites in 100 μL human and rat plasma. Plasma hydrolysis was followed by protein precipitation before analysis. Limits of detection were 0.1 μg L(-1), with linear ranges from 0.25 to 1000 μg L(-1). Process efficiency, matrix effect, total imprecision (%CV) and accuracy (%target) were 36-93%, from -8 to 12%, 2.1 to 7.3% and 86 to 109%, respectively. MDPV and metabolites were stable at room temperature for 24 h, 4 °C for 72 h and after 3 freeze-thaw cycles with less than 10% variability. Human-rat plasma cross validation demonstrated that rat plasma could be accurately quantified against a human plasma calibration curve. As proof of this method, rat plasma specimens were analyzed after intraperitoneal and subcutaneous dosing with MDPV (0.5 mg kg(-1)). MDPV, 3,4-catechol-PV and 4-OH-3-MeO-PV concentrations ranged from not detected to 107.5 μg L(-1) prior to and up to 8h after dosing. This method provides a simultaneous quantification of MDPV and two metabolites in plasma with good selectivity and sensitivity.<br /> (Published by Elsevier B.V.)
- Subjects :
- Animals
Benzodioxoles chemistry
Chromatography, Liquid
Humans
Hydrolysis
Limit of Detection
Linear Models
Male
Pyrrolidines chemistry
Rats
Reproducibility of Results
Synthetic Cathinone
Benzodioxoles blood
Benzodioxoles metabolism
Blood Chemical Analysis methods
Mass Spectrometry
Pyrrolidines blood
Pyrrolidines metabolism
Subjects