Back to Search Start Over

Fibrin-targeted magnetic resonance imaging allows in vivo quantification of thrombus fibrin content and identifies thrombi amenable for thrombolysis.

Authors :
Andia ME
Saha P
Jenkins J
Modarai B
Wiethoff AJ
Phinikaridou A
Grover SP
Patel AS
Schaeffter T
Smith A
Botnar RM
Source :
Arteriosclerosis, thrombosis, and vascular biology [Arterioscler Thromb Vasc Biol] 2014 Jun; Vol. 34 (6), pp. 1193-1198. Date of Electronic Publication: 2014 Apr 10.
Publication Year :
2014

Abstract

Objective: Deep venous thrombosis is a major health problem. Thrombolytic therapies are effective in recanalizing the veins and preventing post-thrombotic complications, but there is no consensus on selection criteria. The aim of this study was to investigate a fibrin-specific MRI contrast agent (EP-2104R) for the accurate quantification of thrombus' fibrin content in vivo and for the identification of thrombus suitable for thrombolysis.<br />Approach and Results: Venous thrombosis was induced in the inferior vena cava of 8- to 10-week-old male BALB/C mice and MRI performed 2, 4, 7, 10, 14, and 21 days later. Eighteen mice were scanned at each time point pre and 2 hours post injection of EP-2104R (8.0 μmol/kg) with 12 mice at each time point used to correlate fibrin contrast uptake with thrombus' histological stage and fibrin content. Six mice at each time point were immediately subjected to intravascular thrombolytic therapy (10 mg/kg of tissue-type plasminogen activator). Mice were imaged to assess response to lytic therapy 24 hours after thrombolytic treatment. Two mice at each time point were scanned post injection of 0.2 mmol/kg of Gd-DTPA (gadolinium with diethylenetriaminepentacetate, Magnevist, Schering AG, Berlin, Germany) for control purpose. Contrast uptake was correlated positively with the fibrin content of the thrombus measured by Western blotting (R(2)=0.889; P<0.001). Thrombus relaxation rate (R1) post contrast and the change in visualized thrombus size on late gadolinium enhancement inversion recovery MRI pre-EP-2104R and post-EP-2104R injection were the best predictors for successful thrombolysis (area under the curve, 0.989 [95% confidence interval, 0.97-1.00] and 0.994 [95% confidence interval, 0.98-1.00] respectively).<br />Conclusions: MRI with a fibrin-specific contrast agent accurately estimates thrombus fibrin content in vivo and identifies thrombi that are amenable for thrombolysis.<br /> (© 2014 American Heart Association, Inc.)

Details

Language :
English
ISSN :
1524-4636
Volume :
34
Issue :
6
Database :
MEDLINE
Journal :
Arteriosclerosis, thrombosis, and vascular biology
Publication Type :
Academic Journal
Accession number :
24723557
Full Text :
https://doi.org/10.1161/ATVBAHA.113.302931