Feasibility and safety of a new generation of gore septal occluder device in children.

Authors :
Lombardi M
Tagliente MR
Pirolo T
Massari E
Milella L
Vairo U
Source :
Journal of cardiovascular medicine (Hagerstown, Md.) [J Cardiovasc Med (Hagerstown)] 2016 Dec; Vol. 17 Suppl 2, pp. e249-e251.
Publication Year :
2016

Abstract

Aim: Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate.<br />Methods: The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device.<br />Results: The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months.<br />Conclusion: The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15 mm or less in childhood.

Details

Language :
English
ISSN :
1558-2035
Volume :
17 Suppl 2
Database :
MEDLINE
Journal :
Journal of cardiovascular medicine (Hagerstown, Md.)
Publication Type :
Editorial & Opinion
Accession number :
24721761
Full Text :
https://doi.org/10.2459/JCM.0000000000000036