Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology.

Authors :
Ellefsen KN
Anizan S
Castaneto MS
Desrosiers NA
Martin TM
Klette KL
Huestis MA
Source :
Drug testing and analysis [Drug Test Anal] 2014 Jul-Aug; Vol. 6 (7-8), pp. 728-38. Date of Electronic Publication: 2014 Mar 21.
Publication Year :
2014

Abstract

Deterrence of synthetic cathinone abuse is hampered by the lack of a high-throughput immunoassay screen. The Randox Drugs of Abuse V (DOA-V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3',4'-methylenedioxypyrovalerone (MDPV)/3',4'-methylenedioxy-α-pyrrolidinobutiophenone (MDPBP). We evaluated DOA-V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer. We screened 20 017 authentic military urine specimens and confirmed positives by liquid chromatography-tandem mass spectrometry (LC-MS/MS) for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2 µg/L (BSII), respectively. Linearity was acceptable (R(2)  >0.98); however, a large negative bias was observed with in-house prepared calibrators. Intra-assay imprecision was <20% BSI-II, while inter-assay imprecision was 18-42% BSI and <22% BSII. Precision was acceptable for Randox controls. Cross-reactivities of many additional synthetic cathinones were determined. Authentic drug-free negative urine pH <4 produced false positive results for BSI (6.3 µg/L) and BSII (473 µg/L). Oxidizing agents reduced BSI and increased BSII results. Sensitivity, specificity, and efficiency of 100%, 52.1%, and 53.0% were obtained at manufacturer's proposed cut-offs (BSI 5 µg/L, BSII 30 µg/L). Performance improved if cut-off concentrations increased (BSI 7.5 µg/L, BSII 40 µg/L); however, there were limited confirmed positive specimens. Currently, this is the first and only fully validated immunoassay for preliminary detection of synthetic cathinones in urine. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.<br /> (Published 2014. This article is a U.S. Government work and is in the public domain in the USA.)

Details

Language :
English
ISSN :
1942-7611
Volume :
6
Issue :
7-8
Database :
MEDLINE
Journal :
Drug testing and analysis
Publication Type :
Academic Journal
Accession number :
24659527
Full Text :
https://doi.org/10.1002/dta.1633