Back to Search
Start Over
Near-threshold (7)Li(p,n)(7)Be neutrons on the practical conditions using thick Li-target and Gaussian proton energies for BNCT.
- Source :
-
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2014 Jun; Vol. 88, pp. 221-4. Date of Electronic Publication: 2014 Jan 08. - Publication Year :
- 2014
-
Abstract
- The near threshold (7)Li(p,n)(7)Be neutrons generated by incident proton energy having Gaussian distribution with mean energies from 1.85 to 1.95MeV, were studied as a practical neutron source for BNCT wherein an RFQ accelerator and a thick Li-target are used. Gaussian energy distributions with the standard deviation of 0, 10, 20 and 40keV for mean proton energies from 1.85 to 1.95MeV were surveyed in 0.01MeV increments. A thick liquid Li-target whose dimensions were established in our previous experiments (i.e., 1mm-thick with 50mm width and 50mm length) was considered in this study. The suitable incident proton energy and physical dimensions of Pb layer which serves as a gamma absorber and a Polyethylene layer which is used as a BDE were surveyed by means of the concepts of TPD. Dose distribution were calculated by using MCNP5. A proton beam with mean energy of 1.92MeV and a Gaussian energy distribution with a standard deviation of 20keV at a current of 10mA was selected from the viewpoint of irradiation time and practically achievable proton current. The suitable thicknesses of Pb gamma absorber was estimated to be about 3cm. The estimated thickness of the polyethylene BDE was about 24mm for an ideal proton current of 13mA, and was 18mm for a practical proton current of 10mA.<br /> (Copyright © 2013 Elsevier Ltd. All rights reserved.)
- Subjects :
- Absorption, Radiation
Beryllium radiation effects
Computer Simulation
Equipment Design
Equipment Failure Analysis
Lithium radiation effects
Materials Testing
Normal Distribution
Protons
Radiometry
Radiotherapy Dosage
Scattering, Radiation
Beryllium chemistry
Boron Neutron Capture Therapy instrumentation
Lithium chemistry
Models, Statistical
Neutrons therapeutic use
Particle Accelerators instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1872-9800
- Volume :
- 88
- Database :
- MEDLINE
- Journal :
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
- Publication Type :
- Academic Journal
- Accession number :
- 24491682
- Full Text :
- https://doi.org/10.1016/j.apradiso.2013.12.024