Back to Search
Start Over
Piezoelectric immunosensors for the detection of individual antibiotics and the total content of penicillin antibiotics in foodstuffs.
- Source :
-
Talanta [Talanta] 2014 Mar; Vol. 120, pp. 312-7. Date of Electronic Publication: 2013 Dec 18. - Publication Year :
- 2014
-
Abstract
- Piezoelectric immunosensors on the basis of homologous and group-specificantibodies have been developed for detecting penicillin G, ampicillin, and the total content of penicillin antibiotics. The receptor coating of the sensor was obtained by the immobilization of penicillin G or ampicillin hapten-protein conjugates on the polypyrrole film obtained by electropolymerization and activated by glutaraldehyde. The affinity constants and the cross reactivity coefficients have been calculated. This made it possible to estimate the affinity and specificity of the polyclonal and monoclonal antibodies used. The calibration curves are linear in the range of concentrations 2.5-250.0 ng ml(-1) (penicillin G), 2.5-500.0 ng ml(-1) (ampicillin), and 1-500 ng ml(-1) (group of penicillin). The limits of detection are 0.8 ng ml(-1), 3.9 ng ml(-1), which are lower than MRL, established for penicillin antibiotics. The sensors were tested in detecting penicillins in milk, pork, beef, liver.<br /> (Copyright © 2013 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-3573
- Volume :
- 120
- Database :
- MEDLINE
- Journal :
- Talanta
- Publication Type :
- Academic Journal
- Accession number :
- 24468375
- Full Text :
- https://doi.org/10.1016/j.talanta.2013.12.018