Abstract
- Background: Left ventricular segmental wall motion analysis is important for clinical decision making in cardiac diseases. Strain analysis with myocardial tissue tagging is the non-invasive gold standard for quantitative assessment, however, it is time-consuming. Cardiovascular magnetic resonance myocardial feature-tracking (CMR-FT) can rapidly perform strain analysis, because it can be employed with standard CMR cine-imaging. The aim is to validate segmental peak systolic circumferential strain (peak SCS) and time to peak systolic circumferential strain (T2P-SCS) analysed by CMR-FT against tissue tagging, and determine its intra and inter-observer variability.<br />Methods: Patients in whom both cine CMR and tissue tagging has been performed were selected. CMR-FT analysis was done using endocardial (CMR-FTendo) and mid-wall contours (CMR-FTmid). The Intra Class Correlation Coefficient (ICC) and Pearson correlation were calculated.<br />Results: 10 healthy volunteers, 10 left bundle branch block (LBBB) and 10 hypertrophic cardiomyopathy patients were selected. With CMR-FT all 480 segments were analyzable and with tissue tagging 464 segments.Significant differences in mean peak SCS values of the total study group were present between CMR-FTendo and tissue tagging (-23.8 ± 9.9% vs -13.4 ± 3.3%, p<0.001). Differences were smaller between CMR-FTmid and tissue tagging (-16.4 ± 6.1% vs -13.4 ± 3.3%, p=0.001). The ICC of the mean peak SCS of the total study group between CMR-FTendo and tissue tagging was low (0.19 (95%-CI-0.10-0.49), p=0.02). Comparable results were seen between CMR-FTmid and tissue tagging. In LBBB patients, mean T2P-SCS values measured with CMR-FTendo and CMR-FTmid were 418 ± 66 ms, 454 ± 60 ms, which were longer than with tissue tagging, 376 ± 55 ms, both p<0.05. ICC of the mean T2P-SCS between CMR-FTendo and tissue tagging was 0.64 (95%-CI-0.36-0.81), p<0.001, this was better in the healthy volunteers and LBBB group, whereas the ICC between CMR-FTmid and tissue tagging was lower.The intra and inter-observer agreement of segmental peak SCS with CMR-FTmid was lower compared with tissue tagging; similar results were seen for segmental T2P-SCS.<br />Conclusions: The intra and inter-observer agreement of segmental peak SCS and T2P-SCS is substantially lower with CMR-FTmid compared with tissue tagging. Therefore, current segmental CMR-FTmid techniques are not yet applicable for clinical and research purposes.
- Subjects :
- Adult
Aged
Biomechanical Phenomena
Cardiomyopathy, Hypertrophic physiopathology
Humans
Male
Middle Aged
Observer Variation
Predictive Value of Tests
Reproducibility of Results
Retrospective Studies
Stress, Mechanical
Stroke Volume
Cardiomyopathy, Hypertrophic diagnosis
Magnetic Resonance Imaging, Cine
Myocardial Contraction
Ventricular Function, Left
Subjects
Details
- Language :
- English
- ISSN :
- 1532-429X
- Volume :
- 16
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
- Publication Type :
- Academic Journal
- Accession number :
- 24450803
- Full Text :
- https://doi.org/10.1186/1532-429X-16-10