Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials.

Authors :
Millett PJ
Warth RJ
Dornan GJ
Lee JT
Spiegl UJ
Source :
Journal of shoulder and elbow surgery [J Shoulder Elbow Surg] 2014 Apr; Vol. 23 (4), pp. 586-97. Date of Electronic Publication: 2014 Jan 08.
Publication Year :
2014

Abstract

Background: The purpose of this study was to perform a systematic review and meta-analysis of all available level I randomized controlled trials comparing single-row with double-row repair to statistically compare clinical outcomes and imaging-diagnosed re-tear rates.<br />Methods: A literature search was undertaken to identify all level I randomized controlled trials comparing structural or clinical outcomes after single-row versus double-row rotator cuff repair. Clinical outcomes measures included in the meta-analysis were the American Shoulder and Elbow Surgeons, University of California-Los Angeles, and Constant scores; structural outcomes included imaging-confirmed re-tears. Meta-analyses compared raw mean differences in outcomes measures and relative risk ratios for imaging-diagnosed re-tears after single-row or double-row repairs by a random-effects model.<br />Results: The literature search identified a total of 7 studies that were included in the meta-analysis. There were no significant differences in preoperative to postoperative change in American Shoulder and Elbow Surgeons, University of California-Los Angeles, or Constant scores between the single-row and double-row groups (P = .440, .116, and .156, respectively). The overall re-tear rate was 25.9% (68/263) in the single-row group and 14.2% (37/261) in the double-row group. There was a statistically significant increased risk of sustaining an imaging-proven re-tear of any type in the single-row group (relative risk, 1.76 [95% confidence interval, 1.25-2.48]; P = .001), with partial-thickness re-tears accounting for the majority of this difference (relative risk, 1.99 [95% confidence interval, 1.40-3.82]; P = .039).<br />Conclusion: Single-row repairs resulted in significantly higher re-tear rates compared with double-row repairs, especially with regard to partial-thickness re-tears. However, there were no detectable differences in improvement in outcomes scores between single-row and double-row repairs.<br /> (Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-6500
Volume :
23
Issue :
4
Database :
MEDLINE
Journal :
Journal of shoulder and elbow surgery
Publication Type :
Academic Journal
Accession number :
24411671
Full Text :
https://doi.org/10.1016/j.jse.2013.10.006