Back to Search Start Over

Pumpless extracorporeal CO(2) removal restores normocapnia and is associated with less regional perfusion in experimental acute lung injury.

Authors :
Kreyer S
Muders T
Luepschen H
Kricklies C
Linden K
Tolba R
Varelmann D
Zinserling J
Putensen C
Wrigge H
Source :
Acta anaesthesiologica Scandinavica [Acta Anaesthesiol Scand] 2014 Jan; Vol. 58 (1), pp. 52-60. Date of Electronic Publication: 2013 Nov 07.
Publication Year :
2014

Abstract

Background: Lung protective ventilation may lead to hypoventilation with subsequent hypercapnic acidosis (HA). If HA cannot be tolerated or occurs despite increasing respiratory rate or buffering, extracorporeal CO2-removal using a percutaneous extracorporeal lung assist (pECLA) is an option. We hypothesised that compensation of HA using pECLA impairs regional perfusion. To test this hypothesis we determined organ blood flows in a lung-injury model with combined hypercapnic and metabolic acidosis.<br />Methods: After induction of lung injury using hydrochloric acid (HCl) aspiration and metabolic acidosis by intravenous HCl infusion in nine pigs, an arterial-venous pECLA device was inserted. In randomised order, four treatments were tested: pECLA shunt (1) with and (2) without HA, and clamped pECLA shunt (3) with and (4) without HA. Regional blood flows were measured with the coloured microsphere technique.<br />Results: HA resulted in higher perfusion in adrenal glands, spleen and parts of splanchnic area (Pā€‰<ā€‰0.05) compared with normocapnia. During CO2-removal with pECLA, regional perfusion decreased to levels comparable with those without pECLA and normocapnia. Cardiac output (CO) increased during HA without a pECLA shunt and was highest during HA with a pECLA shunt compared with normocapnia. During CO2-removal with pECLA, this variable decreased but stayed higher than during normocapnia with clamped pECLA shunt (Pā€‰<ā€‰0.05).<br />Conclusion: In our lung-injury model, HA was associated with increased systemic and regional blood flow in several organs. pECLA provides effective CO2 removal, requiring a higher CO for perfusion of the pECLA device without improvement of regional organ perfusion.<br /> (© 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1399-6576
Volume :
58
Issue :
1
Database :
MEDLINE
Journal :
Acta anaesthesiologica Scandinavica
Publication Type :
Academic Journal
Accession number :
24341694
Full Text :
https://doi.org/10.1111/aas.12217