Back to Search
Start Over
Calcineurin activity assay measurement by liquid chromatography-tandem mass spectrometry in the multiple reaction monitoring mode.
- Source :
-
Clinical chemistry [Clin Chem] 2014 Feb; Vol. 60 (2), pp. 353-60. Date of Electronic Publication: 2013 Nov 26. - Publication Year :
- 2014
-
Abstract
- Background: Blood concentrations of the calcineurin inhibitors (CNIs) cyclosporine and tacrolimus are currently measured to monitor immunosuppression in transplant patients. The measurement of calcineurin (CN) phosphatase activity has been proposed as a complementary pharmacodynamic approach. However, determining CN activity with current methods is not practical. We developed a new method amenable to routine use.<br />Methods: Using liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM-MS), we quantified CN activity by measuring the dephosphorylation of a synthetic phosphopeptide substrate. A stable isotope analog of the product peptide served as internal standard, and a novel inhibitor cocktail minimized dephosphorylation by other major serine/threonine phosphatases. The assay was used to determine CN activity in peripheral blood mononuclear cells (PBMCs) isolated from 20 CNI-treated kidney transplant patients and 9 healthy volunteers.<br />Results: Linearity was observed from 0.16 to 2.5 μmol/L of product peptide, with accuracy in the 15% tolerance range. Intraassay and interassay recoveries were 100.6 (9.6) and 100 (7.5), respectively. Michaelis-Menten kinetics for purified CN were Km = 10.7 (1.6) μmol/L, Vmax = 2.8 (0.3) μmol/min · mg, and for Jurkat lysate, Km = 182.2 (118.0) μmol/L, Vmax = 0.013 (0.006) μmol/min · mg. PBMC CN activity was successfully measured in a single tube with an inhibitor cocktail.<br />Conclusions: Because LC-MRM-MS is commonly used in routine clinical dosage of drugs, this CN activity assay could be applied, with parallel blood drug concentration monitoring, to a large panel of patients to reevaluate the validity of PBMC CN activity monitoring.
- Subjects :
- Adult
Calcineurin Inhibitors
Calibration
Chromatography, High Pressure Liquid instrumentation
Cyclosporine blood
Cyclosporine pharmacology
Cyclosporine therapeutic use
Female
Humans
Immunosuppression Therapy methods
Immunosuppressive Agents blood
Immunosuppressive Agents pharmacology
Immunosuppressive Agents therapeutic use
Jurkat Cells
Kidney Transplantation
Male
Reference Standards
Reproducibility of Results
Substrate Specificity
Tacrolimus blood
Tacrolimus pharmacology
Tacrolimus therapeutic use
Tandem Mass Spectrometry instrumentation
Calcineurin blood
Chromatography, High Pressure Liquid methods
Leukocytes, Mononuclear enzymology
Phosphopeptides chemistry
Tandem Mass Spectrometry methods
Subjects
Details
- Language :
- English
- ISSN :
- 1530-8561
- Volume :
- 60
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Clinical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 24281780
- Full Text :
- https://doi.org/10.1373/clinchem.2013.213264