Back to Search Start Over

An international Ki67 reproducibility study.

Authors :
Polley MY
Leung SC
McShane LM
Gao D
Hugh JC
Mastropasqua MG
Viale G
Zabaglo LA
Penault-Llorca F
Bartlett JM
Gown AM
Symmans WF
Piper T
Mehl E
Enos RA
Hayes DF
Dowsett M
Nielsen TO
Source :
Journal of the National Cancer Institute [J Natl Cancer Inst] 2013 Dec 18; Vol. 105 (24), pp. 1897-906. Date of Electronic Publication: 2013 Nov 07.
Publication Year :
2013

Abstract

Background: In breast cancer, immunohistochemical assessment of proliferation using the marker Ki67 has potential use in both research and clinical management. However, lack of consistency across laboratories has limited Ki67's value. A working group was assembled to devise a strategy to harmonize Ki67 analysis and increase scoring concordance. Toward that goal, we conducted a Ki67 reproducibility study.<br />Methods: Eight laboratories received 100 breast cancer cases arranged into 1-mm core tissue microarrays-one set stained by the participating laboratory and one set stained by the central laboratory, both using antibody MIB-1. Each laboratory scored Ki67 as percentage of positively stained invasive tumor cells using its own method. Six laboratories repeated scoring of 50 locally stained cases on 3 different days. Sources of variation were analyzed using random effects models with log2-transformed measurements. Reproducibility was quantified by intraclass correlation coefficient (ICC), and the approximate two-sided 95% confidence intervals (CIs) for the true intraclass correlation coefficients in these experiments were provided.<br />Results: Intralaboratory reproducibility was high (ICC = 0.94; 95% CI = 0.93 to 0.97). Interlaboratory reproducibility was only moderate (central staining: ICC = 0.71, 95% CI = 0.47 to 0.78; local staining: ICC = 0.59, 95% CI = 0.37 to 0.68). Geometric mean of Ki67 values for each laboratory across the 100 cases ranged 7.1% to 23.9% with central staining and 6.1% to 30.1% with local staining. Factors contributing to interlaboratory discordance included tumor region selection, counting method, and subjective assessment of staining positivity. Formal counting methods gave more consistent results than visual estimation.<br />Conclusions: Substantial variability in Ki67 scoring was observed among some of the world's most experienced laboratories. Ki67 values and cutoffs for clinical decision-making cannot be transferred between laboratories without standardizing scoring methodology because analytical validity is limited.

Details

Language :
English
ISSN :
1460-2105
Volume :
105
Issue :
24
Database :
MEDLINE
Journal :
Journal of the National Cancer Institute
Publication Type :
Academic Journal
Accession number :
24203987
Full Text :
https://doi.org/10.1093/jnci/djt306