Back to Search
Start Over
An international Ki67 reproducibility study.
- Source :
-
Journal of the National Cancer Institute [J Natl Cancer Inst] 2013 Dec 18; Vol. 105 (24), pp. 1897-906. Date of Electronic Publication: 2013 Nov 07. - Publication Year :
- 2013
-
Abstract
- Background: In breast cancer, immunohistochemical assessment of proliferation using the marker Ki67 has potential use in both research and clinical management. However, lack of consistency across laboratories has limited Ki67's value. A working group was assembled to devise a strategy to harmonize Ki67 analysis and increase scoring concordance. Toward that goal, we conducted a Ki67 reproducibility study.<br />Methods: Eight laboratories received 100 breast cancer cases arranged into 1-mm core tissue microarrays-one set stained by the participating laboratory and one set stained by the central laboratory, both using antibody MIB-1. Each laboratory scored Ki67 as percentage of positively stained invasive tumor cells using its own method. Six laboratories repeated scoring of 50 locally stained cases on 3 different days. Sources of variation were analyzed using random effects models with log2-transformed measurements. Reproducibility was quantified by intraclass correlation coefficient (ICC), and the approximate two-sided 95% confidence intervals (CIs) for the true intraclass correlation coefficients in these experiments were provided.<br />Results: Intralaboratory reproducibility was high (ICC = 0.94; 95% CI = 0.93 to 0.97). Interlaboratory reproducibility was only moderate (central staining: ICC = 0.71, 95% CI = 0.47 to 0.78; local staining: ICC = 0.59, 95% CI = 0.37 to 0.68). Geometric mean of Ki67 values for each laboratory across the 100 cases ranged 7.1% to 23.9% with central staining and 6.1% to 30.1% with local staining. Factors contributing to interlaboratory discordance included tumor region selection, counting method, and subjective assessment of staining positivity. Formal counting methods gave more consistent results than visual estimation.<br />Conclusions: Substantial variability in Ki67 scoring was observed among some of the world's most experienced laboratories. Ki67 values and cutoffs for clinical decision-making cannot be transferred between laboratories without standardizing scoring methodology because analytical validity is limited.
Details
- Language :
- English
- ISSN :
- 1460-2105
- Volume :
- 105
- Issue :
- 24
- Database :
- MEDLINE
- Journal :
- Journal of the National Cancer Institute
- Publication Type :
- Academic Journal
- Accession number :
- 24203987
- Full Text :
- https://doi.org/10.1093/jnci/djt306