Validation of an improved competitive enzyme-linked immunosorbent assay to detect Equine arteritis virus antibody.

Authors :
Chung C
Wilson C
Timoney P
Balasuriya U
Adams E
Adams DS
Evermann JF
Clavijo A
Shuck K
Rodgers S
Lee SS
McGuire TC
Source :
Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc [J Vet Diagn Invest] 2013 Nov; Vol. 25 (6), pp. 727-35.
Publication Year :
2013

Abstract

The objective of the present study was to validate a previously described competitive enzyme-linked immunosorbent assay (cELISA) to detect antibody to Equine arteritis virus (EAV) based on GP5-specific nonneutralizing monoclonal antibody (mAb) 17B7(9) using the World Organization for Animal Health (OIE)-recommended protocol, which includes the following 5 in-house analyses. 1) The assay was calibrated with the OIE-designated reference serum panel for EAV; 2) repeatability was evaluated within and between assay runs; 3) analytical specificity was evaluated using sera specific to related viruses; 4) analytical sensitivity was evaluated with sera from horses vaccinated with an EAV modified live virus (MLV) vaccine; and 5) the duration of cELISA antibody detection following EAV vaccination was determined. The positive cELISA cutoff of ≥35% inhibition (%I) was confirmed by receiver operating characteristic plot analysis. Analytical sensitivity of the cELISA was comparable to the serum neutralization (SN) assay in that it detected EAV-specific antibody as early as 8 days postvaccination. The duration of EAV-specific antibody detected by cELISA was over 5 years after the last vaccination. This cELISA could detect EAV-specific antibody in serum samples collected from horses infected with various EAV strains. In the field trial performed by American Association of Veterinary Laboratory Diagnosticians-accredited state laboratories and OIE laboratory, the diagnostic specificity of the cELISA was 99.5% and the diagnostic sensitivity was 98.2%. The data using various serum panels also had consistently significant positive correlation between SN titers and cELISA %I results. The results further confirm that the EAV antibody cELISA is a reliable, simple alternative to the SN assay for detecting EAV-specific antibodies in equine sera.

Details

Language :
English
ISSN :
1943-4936
Volume :
25
Issue :
6
Database :
MEDLINE
Journal :
Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc
Publication Type :
Academic Journal
Accession number :
24202992
Full Text :
https://doi.org/10.1177/1040638713508401