Detecting radiation-induced injury using rapid 3D variogram analysis of CT images of rat lungs.
- Source :
-
Academic radiology [Acad Radiol] 2013 Oct; Vol. 20 (10), pp. 1264-71. - Publication Year :
- 2013
-
Abstract
- Rationale and Objectives: To investigate the ability of variogram analysis of octree-decomposed computed tomography (CT) images and volume change maps to detect radiation-induced damage in rat lungs.<br />Materials and Methods: The lungs of female Sprague-Dawley rats were exposed to one of five absorbed doses (0, 6, 9, 12, or 15 Gy) of gamma radiation from a Co-60 source. At 6 months postexposure, pulmonary function tests were performed and four-dimensional (4D) CT images were acquired using a respiratory-gated microCT scanner. Volume change maps were then calculated from the 4DCT images. Octree decomposition was performed on CT images and volume change maps, and variogram analysis was applied to the decomposed images. Correlations of measured parameters with dose were evaluated.<br />Results: The effects of irradiation were not detectable from measured parameters, indicating only mild lung damage. Additionally, there were no significant correlations of pulmonary function results or CT densitometry with radiation dose. However, the variogram analysis did detect a significant correlation with dose in both the CT images (r = -0.57, P = .003) and the volume change maps (r = -0.53, P = .008).<br />Conclusion: This is the first study to use variogram analysis of lung images to assess pulmonary damage in a model of radiation injury. Results show that this approach is more sensitive to detecting radiation damage than conventional measures such as pulmonary function tests or CT densitometry.<br /> (Copyright © 2013 AUR. All rights reserved.)
- Subjects :
- Animals
Female
Radiation Dosage
Radiometry methods
Rats
Rats, Sprague-Dawley
Reproducibility of Results
Sensitivity and Specificity
Algorithms
Imaging, Three-Dimensional methods
Radiation Pneumonitis diagnostic imaging
Radiation Pneumonitis etiology
Radiographic Image Interpretation, Computer-Assisted methods
Tomography, X-Ray Computed adverse effects
Tomography, X-Ray Computed methods