Back to Search Start Over

Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.

Authors :
Farshad-Amacker NA
Alkadhi H
Leschka S
Frauenfelder T
Source :
Academic radiology [Acad Radiol] 2013 Oct; Vol. 20 (10), pp. 1234-9.
Publication Year :
2013

Abstract

Rationale and Objectives: To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts.<br />Materials and Methods: Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))).<br />Results: The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P < .05).<br />Conclusion: High-pitch DSCT significantly decreases motion artifacts in various directions and improves image quality.<br /> (Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1878-4046
Volume :
20
Issue :
10
Database :
MEDLINE
Journal :
Academic radiology
Publication Type :
Academic Journal
Accession number :
24029055
Full Text :
https://doi.org/10.1016/j.acra.2013.07.003