Back to Search
Start Over
Drug screening in medical examiner casework by high-resolution mass spectrometry (UPLC-MSE-TOF).
- Source :
-
Journal of analytical toxicology [J Anal Toxicol] 2013 Oct; Vol. 37 (8), pp. 580-93. Date of Electronic Publication: 2013 Sep 01. - Publication Year :
- 2013
-
Abstract
- Postmortem drug findings yield important analytical evidence in medical examiner casework, and chromatography coupled with nominal mass spectrometry (MS) serves as the predominant general unknown screening approach. We report screening by ultra performance liquid chromatography (UPLC) coupled with hybrid quadrupole time-of-flight mass spectrometer (MS(E)-TOF), with comparison to previously validated nominal mass UPLC-MS and UPLC-MS-MS methods. UPLC-MS(E)-TOF screening for over 950 toxicologically relevant drugs and metabolites was performed in a full-spectrum (m/z 50-1,000) mode using an MS(E) acquisition of both molecular and fragment ion data at low (6 eV) and ramped (10-40 eV) collision energies. Mass error averaged 1.27 ppm for a large panel of reference drugs and metabolites. The limit of detection by UPLC-MS(E)-TOF ranges from 0.5 to 100 ng/mL and compares closely with UPLC-MS-MS. The influence of column recovery and matrix effect on the limit of detection was demonstrated with ion suppression by matrix components correlating closely with early and late eluting reference analytes. Drug and metabolite findings by UPLC-MS(E)-TOF were compared with UPLC-MS and UPLC-MS-MS analyses of postmortem blood in 300 medical examiner cases. Positive findings by all methods totaled 1,528, with a detection rate of 57% by UPLC-MS, 72% by UPLC-MS-MS and 80% by combined UPLC-MS and UPLC-MS-MS screening. Compared with nominal mass screening methods, UPLC-MS(E)-TOF screening resulted in a 99% detection rate and, in addition, offered the potential for the detection of nontargeted analytes via high-resolution acquisition of molecular and fragment ion data.
- Subjects :
- Adult
Calibration
Female
Forensic Toxicology instrumentation
Humans
Limit of Detection
Male
Middle Aged
Postmortem Changes
Reference Standards
Reproducibility of Results
Chromatography, High Pressure Liquid methods
Coroners and Medical Examiners
Drug-Related Side Effects and Adverse Reactions blood
Forensic Toxicology methods
Pharmaceutical Preparations blood
Tandem Mass Spectrometry methods
Subjects
Details
- Language :
- English
- ISSN :
- 1945-2403
- Volume :
- 37
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Journal of analytical toxicology
- Publication Type :
- Academic Journal
- Accession number :
- 23999055
- Full Text :
- https://doi.org/10.1093/jat/bkt071