Back to Search Start Over

Low accuracy of tumor markers for diagnosing pancreatic neuroendocrine tumors in multiple endocrine neoplasia type 1 patients.

Authors :
de Laat JM
Pieterman CR
Weijmans M
Hermus AR
Dekkers OM
de Herder WW
van der Horst-Schrivers AN
Drent ML
Bisschop PH
Havekes B
Vriens MR
Valk GD
Source :
The Journal of clinical endocrinology and metabolism [J Clin Endocrinol Metab] 2013 Oct; Vol. 98 (10), pp. 4143-51. Date of Electronic Publication: 2013 Aug 16.
Publication Year :
2013

Abstract

Context: The assessment of tumor markers for diagnosing pancreatic neuroendocrine tumors (pNET) in multiple endocrine neoplasia type 1 (MEN1) patients is advised in the current guidelines but has never been validated for this purpose.<br />Objective: The objective of the study was to assess the diagnostic accuracy of chromogranin A (CgA), pancreatic polypeptide (PP), and glucagon for pNET in MEN1.<br />Design: This was a diagnostic study.<br />Setting: The study was conducted at Dutch university medical centers from 2008 to 2011, representing 90% of the total Dutch MEN1 population.<br />Patients and Methods: Patients for whom data on tumor markers in combination with the reference standard (ie, radiological imaging) were available between 2008 and 2011 were included. The reference standard for the presence of pNET was pathology or detection on magnetic resonance imaging, computed tomography, or endoscopic ultrasound confirmed on subsequent imaging, irrespective of modality at follow-up.<br />Main Outcome Measures: The area under the receiver-operating characteristic curve (AUC), positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, sensitivity, and specificity were calculated for each marker.<br />Results: For the analysis of PP, CgA, and glucagon, 73, 81, and 94 patients were available, respectively. The AUC for CgA was 0.48 [95% confidence interval (CI) 0.35-0.61] with a sensitivity 0.33 and a specificity 0.73; the AUC for glucagon was 0.58 (95% CI 0.46-0.70) with a sensitivity 0.43 and a specificity 0.73; and the AUC for PP was 0.64 (95% CI 0.50-0.77) with a sensitivity 0.36 and a specificity 0.74. Age, imaging modality, tumor size, and number did not influence the outcomes.<br />Conclusion: The diagnostic accuracy of the tumor markers CgA, PP, and glucagon for pNET in MEN1 is low.

Details

Language :
English
ISSN :
1945-7197
Volume :
98
Issue :
10
Database :
MEDLINE
Journal :
The Journal of clinical endocrinology and metabolism
Publication Type :
Academic Journal
Accession number :
23956349
Full Text :
https://doi.org/10.1210/jc.2013-1800