Back to Search
Start Over
Effect of through-plane and twisting motion on left ventricular strain calculation: direct comparison between two-dimensional and three-dimensional speckle-tracking echocardiography.
- Source :
-
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography [J Am Soc Echocardiogr] 2013 Nov; Vol. 26 (11), pp. 1274-1281.e4. Date of Electronic Publication: 2013 Aug 14. - Publication Year :
- 2013
-
Abstract
- Background: The aim of this study was to investigate the effect of out-of-plane motion on discrepancies in strain measurements between two-dimensional (2D) and three-dimensional (3D) echocardiography.<br />Methods: Two-dimensional and 3D data sets were acquired in 54 patients. Using 2D and 3D speckle-tracking software, global circumferential strain (CS) and longitudinal strain (LS) as well as CS and LS at three left ventricular (LV) levels was measured. The effect of through-plane motion was assessed by mitral annular displacement.<br />Results: Although a good correlation of global CS was noted between the two methods (r = 0.80, P < .01), mean values of global CS were significantly higher on 3D compared with 2D echocardiography. Correlations of CS and their mean differences were 0.65 and -4.61 at the basal level, 0.76 and -4.17 at the midventricular level, and 0.60 and -2.23 at the apical level, respectively. Correlation of global CS between the two methods was higher in patients who showed mitral annular displacement < 9.4 mm (r = 0.81) compared with those with mitral annular displacement ≥ 9.4 mm (r = 0.61). A good correlation of global LS (r = 0.89, P < .01) was noted, with no significant bias. Correlations of LS and their mean differences were 0.52 and 1.59 at the basal level, 0.89 and -1.17 at the midventricular level, and 0.73 and 1.46 at the apical level, respectively. Correlation of LS between the two methods was higher in patients who showed LV twist < 12.2° (r = 0.94) compared with patients with LV twist ≥ 12.2° (r = 0.68).<br />Conclusions: Through-plane motion produced discrepancies in CS measurements, especially at the LV basal level. Larger bias of LS at the basal and apical LV levels compared with the midventricular level between the two methods suggests that LV twisting also affects the calculation of 2D LS.<br /> (Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.)
- Subjects :
- Adolescent
Adult
Aged
Aged, 80 and over
Elastic Modulus
Female
Humans
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Young Adult
Artifacts
Echocardiography methods
Echocardiography, Three-Dimensional methods
Elasticity Imaging Techniques methods
Ventricular Dysfunction, Left diagnostic imaging
Ventricular Dysfunction, Left physiopathology
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6795
- Volume :
- 26
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
- Publication Type :
- Academic Journal
- Accession number :
- 23953702
- Full Text :
- https://doi.org/10.1016/j.echo.2013.07.006