Objectively measured vs self-reported compliance during oral appliance therapy for sleep-disordered breathing.
- Source :
-
Chest [Chest] 2013 Nov; Vol. 144 (5), pp. 1495-1502. - Publication Year :
- 2013
-
Abstract
- Background: Assessment of the overall therapeutic effectiveness of oral appliance therapy can only be realized through objectively measured compliance. The aims of this study were to assess objectively measured compliance during oral appliance therapy at 1-year follow-up and to compare these data with self-reported use.<br />Methods: Fifty-one eligible patients were enrolled in this 1-year prospective clinical study (men, 61%; mean age, 49 ± 10 years; apnea-hypopnea index, 18.0 ± 11.9 events/h sleep; BMI, 26.6 ± 4.1 kg/m²). Objective compliance during oral appliance therapy at 1-year follow-up was assessed with a microsensor thermometer. Subjective compliance was assessed by self-report. Patients with a mean objectively measured use of ≥ 4 h/night on 70% of nights monitored were considered regular users. The mean disease alleviation was calculated as a measure of overall therapeutic effectiveness.<br />Results: High agreement between objective and subjective compliance data at 1-year follow-up was reported (intraclass correlation coefficient, 0.8; 95% CI, 0.5-0.9), showing a mean subjective overestimation of 30 min (95% CI, -3.1 to 1.9; P = .02). The discontinuation rate at 1-year follow-up was 9.8%. The objective mean use rate was 6.4 ± 1.7 h/night at 1-year follow-up in continuing users, with a regular use rate of 83%. The mean disease alleviation was 54.9%.<br />Conclusions: This study is the first to our knowledge to report the 1-year results of objectively measured compliance during oral appliance therapy. In addition, a high agreement between objective and subjective compliance data were reported, with a mean subjective overestimation of 30 min.<br />Trial Registry: ClinicalTrials.gov; No.: NCT01284881; URL: www.clinicaltrials.gov.
- Subjects :
- Equipment Design
Female
Follow-Up Studies
Humans
Male
Middle Aged
Monitoring, Physiologic
Polysomnography
Prospective Studies
Sleep Apnea Syndromes physiopathology
Treatment Outcome
Continuous Positive Airway Pressure instrumentation
Patient Compliance
Self Report
Sleep
Sleep Apnea Syndromes therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1931-3543
- Volume :
- 144
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Chest
- Publication Type :
- Academic Journal
- Accession number :
- 23928873
- Full Text :
- https://doi.org/10.1378/chest.13-0613