Back to Search Start Over

Fetal echocardiography and pulsed-wave Doppler ultrasound in a rabbit model of intrauterine growth restriction.

Authors :
Hodges R
Endo M
La Gerche A
Eixarch E
DeKoninck P
Ferferieva V
D'hooge J
Wallace EM
Deprest J
Source :
Journal of visualized experiments : JoVE [J Vis Exp] 2013 Jun 29 (76). Date of Electronic Publication: 2013 Jun 29.
Publication Year :
2013

Abstract

Fetal intrauterine growth restriction (IUGR) results in abnormal cardiac function that is apparent antenatally due to advances in fetoplacental Doppler ultrasound and fetal echocardiography. Increasingly, these imaging modalities are being employed clinically to examine cardiac function and assess wellbeing in utero, thereby guiding timing of birth decisions. Here, we used a rabbit model of IUGR that allows analysis of cardiac function in a clinically relevant way. Using isoflurane induced anesthesia, IUGR is surgically created at gestational age day 25 by performing a laparotomy, exposing the bicornuate uterus and then ligating 40-50% of uteroplacental vessels supplying each gestational sac in a single uterine horn. The other horn in the rabbit bicornuate uterus serves as internal control fetuses. Then, after recovery at gestational age day 30 (full term), the same rabbit undergoes examination of fetal cardiac function. Anesthesia is induced with ketamine and xylazine intramuscularly, then maintained by a continuous intravenous infusion of ketamine and xylazine to minimize iatrogenic effects on fetal cardiac function. A repeat laparotomy is performed to expose each gestational sac and a microultrasound examination (VisualSonics VEVO 2100) of fetal cardiac function is performed. Placental insufficiency is evident by a raised pulsatility index or an absent or reversed end diastolic flow of the umbilical artery Doppler waveform. The ductus venosus and middle cerebral artery Doppler is then examined. Fetal echocardiography is performed by recording B mode, M mode and flow velocity waveforms in lateral and apical views. Offline calculations determine standard M-mode cardiac variables, tricuspid and mitral annular plane systolic excursion, speckle tracking and strain analysis, modified myocardial performance index and vascular flow velocity waveforms of interest. This small animal model of IUGR therefore affords examination of in utero cardiac function that is consistent with current clinical practice and is therefore useful in a translational research setting.

Details

Language :
English
ISSN :
1940-087X
Issue :
76
Database :
MEDLINE
Journal :
Journal of visualized experiments : JoVE
Publication Type :
Academic Journal
Accession number :
23852345
Full Text :
https://doi.org/10.3791/50392