Back to Search
Start Over
Cardiac device complications in the cognitively impaired.
- Source :
-
Pacing and clinical electrophysiology : PACE [Pacing Clin Electrophysiol] 2013 Sep; Vol. 36 (9), pp. 1061-7. Date of Electronic Publication: 2013 Jul 03. - Publication Year :
- 2013
-
Abstract
- Background: Patients with preexisting mild cognitive impairment or dementia may be at increased risk for developing cardiac device complications due to an impaired ability to follow postimplant care instructions. We sought to determine whether rates of infection, lead dislodgement, or appropriate or inappropriate implantable cardioverter defibrillator (ICD) shocks are increased in this population.<br />Methods: Medical charts of 561 patients with mild cognitive impairment or dementia who underwent pacemaker (PM) or ICD implantation between January 2002 and October 2009 at Mayo Clinic were identified. A total of 134 patients who were diagnosed with cognitive impairment or dementia before device implantation or within 1 year of implantation were compared with 134 matched controls. Information was collected on patient characteristics, comorbid medical conditions, ejection fraction, complications, device type, device therapy, and mortality. Device information was prospectively entered into a database and retrospectively reviewed.<br />Results: Of the 134 patients with mild cognitive impairment and dementia, 99 underwent PM implantation and 35 underwent ICD implantation. Compared to controls, there was no difference in patient characteristics, ejection fraction, or comorbidities except for diabetes, which was more prevalent in the cognitively impaired and demented group (18.7% vs 30.6%, P = 0.02). There was no difference in device therapy and complications (14.4% vs 5.8%, P = 0.268). However, there was a decreased survival in patients with cognitive impairment and dementia when compared to the control group (42% vs 67% at 5 years, P = 0.007).<br />Conclusion: Patients with cognitive impairment and standard device indications are not at increased risk for device complications and therapy but their survival is much lower than in matched controls. The cause of this lower survival is unknown but may be related to the underlying neurological disease. Presence of cognitive impairment should therefore be considered when contemplating implantation of a cardiac device.<br /> (©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.)
- Subjects :
- Adult
Aged
Aged, 80 and over
Causality
Cognition Disorders psychology
Cognition Disorders rehabilitation
Comorbidity
Defibrillators, Implantable psychology
Dementia psychology
Dementia rehabilitation
Electric Injuries psychology
Female
Humans
Incidence
Male
Middle Aged
Minnesota epidemiology
Pacemaker, Artificial psychology
Patient Compliance psychology
Patient Compliance statistics & numerical data
Prosthesis Failure
Prosthesis-Related Infections psychology
Retrospective Studies
Risk Factors
Survival Analysis
Survival Rate
Cognition Disorders mortality
Defibrillators, Implantable statistics & numerical data
Dementia mortality
Electric Injuries mortality
Pacemaker, Artificial statistics & numerical data
Prosthesis-Related Infections mortality
Registries
Subjects
Details
- Language :
- English
- ISSN :
- 1540-8159
- Volume :
- 36
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Pacing and clinical electrophysiology : PACE
- Publication Type :
- Academic Journal
- Accession number :
- 23822919
- Full Text :
- https://doi.org/10.1111/pace.12205