Back to Search Start Over

Stent thrombosis with second- versus first-generation drug-eluting stents in real-world percutaneous coronary intervention: analysis of 3806 consecutive procedures from a large-volume single-center prospective registry.

Authors :
Dores H
Raposo L
Campante Teles R
Machado C
Leal S
Araújo Gonçalves P
Mesquita Gabriel H
Sousa Almeida M
Mendes M
Source :
The Journal of invasive cardiology [J Invasive Cardiol] 2013 Jul; Vol. 25 (7), pp. 330-6.
Publication Year :
2013

Abstract

Background and Aims: When compared to their first-generation (1stGEN) counterparts, second-generation (2ndGEN) drug-eluting stents (DESs) have been associated with better clinical outcomes in randomized clinical trials, namely by reducing the rates of stent thrombosis (ST). Our goal was to investigate whether or not the broad use of newer devices would translate into higher safety in a real-world population. For that purpose, we compared the occurrence of definite ST at 12 months between two patient subsets from a large-volume single-center registry, according to the type of DES used. Total mortality was a secondary endpoint.<br />Methods and Results: Between January 2003 and December 2010, a total of 3806 patients were submitted to percutaneous coronary intervention (PCI) with only 1stGEN or 2ndGEN DES: 2388 patients (62.7%) were treated with 1stGEN DES only (sirolimus-eluting stent [SES] = 1295 [34.0%]; paclitaxel-eluting stent [PES] = 943 [24.8%]; both stent types were used in 150 patients) and 1418 patients (37.3%) were treated with 2ndGEN DESs only. The total incidence of definite ST (as defined by the Academic Research Consortium) at 12 months was 1.2% (n = 46). After correction for baseline differences between study groups and other variables deemed to influence the occurrence of ST, the use of 1stGEN DES was associated with a significant 2.4-fold increase in the risk of definite ST (95% confidence interval [CI], 1.05-5.42; P=.039) at 12 months; adjusted risk was higher with PES (hazard ratio [HR], 3.6; 95% CI, 1.48-8.70; P=.005) than with SES (HR, 2.3; 95% CI, 0.92-5.65; P=.074). Total mortality (3.7% vs 3.5%) did not differ significantly between groups (adjusted HR, 1.2; 95% CI, 0.81-1.84, P=.348).<br />Conclusions: Our data suggest that in the real-world setting of contemporary PCI, the unrestricted use of newer 2ndGEN DESs translates into an improvement in PCI safety (relative to 1stGEN DESs), with a significantly lower risk of definite ST at 12 months.

Details

Language :
English
ISSN :
1557-2501
Volume :
25
Issue :
7
Database :
MEDLINE
Journal :
The Journal of invasive cardiology
Publication Type :
Academic Journal
Accession number :
23813060