Clinical outcomes of the Realize Adjustable Gastric Band-C at 2 years in a United States population.
- Source :
-
Surgery for obesity and related diseases : official journal of the American Society for Bariatric Surgery [Surg Obes Relat Dis] 2013 Nov-Dec; Vol. 9 (6), pp. 885-93. Date of Electronic Publication: 2013 Mar 14. - Publication Year :
- 2013
-
Abstract
- Background: In 2008, the Realize Band (RB) adopted a precurved design (RB-C). We present 2-year outcomes data from the first multiinstitutional study of RB-C. The objective of this study was to analyze weight loss and safety data from bariatric practices in the United States, including academic, nonacademic, public, and private.<br />Methods: The study included adult RB-C patients with a preoperative body mass index (BMI)≥40 kg/m(2) or >35 kg/m(2) with co-morbidity. Exclusions included RB-C's label contraindications for use. Outcomes parameters were percent excess weight loss (%EWL), BMI change, number and volume of band adjustments, and adverse events.<br />Results: A total of 231 patients met inclusion/exclusion criteria. Of these, 161 had 24-month data available. Mean %EWL was 44.4%±26.9% (P<.0001). BMI decreased from 44.1±5.7 kg/m(2) to 35.3±6.9 kg/m(2) (P<.0001). Percent EWL varied by preoperative BMI (P = .0002), bariatric practice (P<.0001), aftercare frequency (P = .0004), and band fill frequency (P = .0271), but %EWL was not influenced by gender, race, or age (P>.20 each). Adverse events were dysphagia (21.2%), gastroesophageal reflux (21.6%), and vomiting (30.7%). Incidence of pouch dilation, esophageal dilation, and slippage was ≤1%. Revisions (2.2%) were for unbuckled band, tube kinking, slippage, and suspected band leak (1 each). No erosions, explants, or mortality were reported.<br />Conclusion: RB-C appears to be as well tolerated and effective as the first generation RB for weight loss. The near 45% EWL at 2 years is consistent with other high-quality publications on the RB. Preoperative BMI and frequency of postoperative care, including frequency of band fills, influence %EWL. Significant weight loss is achievable with RB-C despite variable postoperative management practices. The low morbidity and the absence of mortality at 24 months reflect positively on the RB-C characteristics.<br /> (Copyright © 2013 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Body Mass Index
Female
Follow-Up Studies
Humans
Longitudinal Studies
Male
Middle Aged
Obesity, Morbid diagnosis
Postoperative Complications physiopathology
Postoperative Complications surgery
Prosthesis Failure
Reoperation methods
Retrospective Studies
Risk Assessment
Time Factors
Treatment Outcome
United States
Weight Loss
Gastroplasty adverse effects
Gastroplasty instrumentation
Obesity, Morbid surgery
Prosthesis Design
Subjects
Details
- Language :
- English
- ISSN :
- 1878-7533
- Volume :
- 9
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Surgery for obesity and related diseases : official journal of the American Society for Bariatric Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 23642493
- Full Text :
- https://doi.org/10.1016/j.soard.2013.02.009