Back to Search Start Over

Bipolar versus multipolar radiofrequency (RF) ablation for the treatment of renal cell carcinoma: differences in technical and clinical parameters.

Authors :
Sommer CM
Lemm G
Hohenstein E
Stampfl U
Bellemann N
Teber D
Rassweiler J
Kauczor HU
Radeleff BA
Pereira PL
Source :
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group [Int J Hyperthermia] 2013; Vol. 29 (1), pp. 21-9.
Publication Year :
2013

Abstract

Purpose: This study aimed to compare retrospectively bipolar RF ablation with multipolar RF ablation for the treatment of renal cell carcinoma.<br />Materials and Methods: Between March 2009 and June 2012, 12 tumours (nine patients) treated with bipolar RF ablation (one applicator) and 14 tumours (11 patients) treated with multipolar RF ablation (two applicators) were compared systematically. Selection between bipolar RF ablation and multipolar RF ablation was operator choice considering tumour size. Study goals included differences in tumour and coagulation extent, and technical parameters (total RF energy delivery and RF ablation time per coagulation volume).<br />Results: Tumour maximum diameter was significantly larger for multipolar RF ablation compared with bipolar RF ablation (27.0 mm versus 19.4 mm; p < 0.01). This difference is partially dependent on operator choice. Coagulation length, width and volume were significantly larger for multipolar RF ablation compared with bipolar RF ablation (35.0 mm versus 26.5 mm, 27.5 mm versus 23.0 mm and 14.3 cm(3) versus 8.1 cm(3); p < 0.01, p < 0.05 and p < 0.05, respectively). Coagulation circularity was not significantly different between both study groups (0.8 versus 0.8; not significant). Total RF energy delivery was significantly higher and RF ablation time per coagulation volume was significantly shorter for multipolar RF ablation compared with bipolar RF ablation (52.0 kJ versus 28.6 kJ and 2.4 min/cm(3) versus 4.1 min/cm(3); p < 0.05 and p < 0.05, respectively).<br />Conclusions: Multipolar RF ablation creates a significantly larger coagulation width, but identical coagulation shape, compared with bipolar RF ablation. Additionally, multipolar RF ablation coagulates faster according to the shorter RF ablation time per coagulation volume.

Details

Language :
English
ISSN :
1464-5157
Volume :
29
Issue :
1
Database :
MEDLINE
Journal :
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group
Publication Type :
Academic Journal
Accession number :
23311376
Full Text :
https://doi.org/10.3109/02656736.2012.750015