Back to Search
Start Over
Survival of patients receiving a primary prevention implantable cardioverter-defibrillator in clinical practice vs clinical trials.
- Source :
-
JAMA [JAMA] 2013 Jan 02; Vol. 309 (1), pp. 55-62. - Publication Year :
- 2013
-
Abstract
- Importance: Randomized clinical trials have shown that implantable cardioverter-defibrillator (ICD) therapy saves lives. Whether the survival of patients who received an ICD in primary prevention clinical trials differs from that of trial-eligible patients receiving a primary prevention ICD in clinical practice is unknown.<br />Objective: To determine whether trial-eligible patients who received a primary prevention ICD as documented in a large national registry have a survival rate that differs from the survival rate of similar patients who received an ICD in the 2 largest primary prevention clinical trials, MADIT-II (n = 742) and SCD-HeFT (n = 829).<br />Design, Setting, and Patients: Retrospective analysis of data for patients enrolled in the National Cardiovascular Data Registry ICD Registry between January 1, 2006, and December 31, 2007, meeting the MADIT-II criteria (2464 propensity score-matched patients) or the SCD-HeFT criteria (3352 propensity score-matched patients). Mortality data for the registry patients were collected through December 31, 2009.<br />Main Outcome Measures: Cox proportional hazards models were used to compare mortality from any cause.<br />Results: The median follow-up time in MADIT-II, SCD-HeFT, and the ICD Registry was 19.5, 46.1, and 35.2 months, respectively. Compared with patients enrolled in the clinical trials, patients in the ICD Registry were significantly older and had a higher burden of comorbidities. In the matched cohorts, there was no significant difference in survival between MADIT-II-like patients in the registry and MADIT-II patients randomized to receive an ICD (2-year mortality rates: 13.9% and 15.6%, respectively; adjusted ICD Registry vs trial hazard ratio, 1.06; 95% CI, 0.85-1.31; P = .62). Likewise, the survival among SCD-HeFT-like patients in the registry was not significantly different from survival among patients randomized to receive ICD therapy in SCD-HeFT (3-year mortality rates: 17.3% and 17.4%, respectively; adjusted registry vs trial hazard ratio, 1.16; 95% CI, 0.97-1.38; P = .11).<br />Conclusions and Relevance: There was no significant difference in survival between clinical trial patients randomized to receive an ICD and a similar group of clinical registry patients who received a primary prevention ICD. Our findings support the continued use of primary prevention ICDs in similar patients seen in clinical practice.<br />Trial Registration: clinicaltrials.gov Identifier: NCT00000609.
- Subjects :
- Age Factors
Aged
Cause of Death
Comorbidity
Death, Sudden, Cardiac prevention & control
Eligibility Determination
Female
Humans
Male
Middle Aged
Primary Prevention
Propensity Score
Randomized Controlled Trials as Topic
Registries statistics & numerical data
Retrospective Studies
Survival Analysis
Defibrillators, Implantable statistics & numerical data
Heart Failure mortality
Heart Failure therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1538-3598
- Volume :
- 309
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- JAMA
- Publication Type :
- Academic Journal
- Accession number :
- 23280225
- Full Text :
- https://doi.org/10.1001/jama.2012.157182