Comparison of white and red blood cell estimates in urine sediment with hemocytometer and automated counts in dogs and cats.

Authors :
O'Neil E
Burton S
Horney B
MacKenzie A
Source :
Veterinary clinical pathology [Vet Clin Pathol] 2013 Mar; Vol. 42 (1), pp. 78-84. Date of Electronic Publication: 2012 Dec 03.
Publication Year :
2013

Abstract

Background: Therapeutic decisions regarding urinalysis are commonly based on the presence of white and red blood cells. Traditionally, numbers per high-power field are estimated using wet-mount microscopic examination. This technique is not standardized and counts are likely prone to inaccuracy. In addition, differentiation of leukocyte types is not possible.<br />Objectives: The aims of this study were to (1) compare WBC and RBC estimates using wet-mount examination with counts obtained using a hemocytometer, (2) assess if a hematology automated analyzer (Sysmex ST-2000iV/XT) provides reliable WBC and RBC counts in urine comparable to hemocytometer counts, and (3) evaluate air-dried Wright-Giemsa-stained urine drop sediment preparations for the determination of differential leukocyte counts.<br />Methods: WBC and RBC counts were obtained by performing wet-mount estimates, manual hemocytometer counts, and Sysmex automated counts on 219 canine and feline urine samples. Results were correlated using Spearman rank correlation. Air-dried Wright-Giemsa stained sediment drop preparations (n = 215) were examined for differential counts of leukocytes.<br />Results: A low but significant association was found between WBC estimates on wet-mount examination and hemocytometer counts (rho = 0.37, P < .01). There was a high and significant association when RBC counts were compared between wet-mount and hemocytometer evaluation (rho = 0.7, P < .01). There was very high and significant interassay correlation between Sysmex data from duplicate samples for what the analyzer classified as WBC (rho = 0.97, P < .01) and RBC (rho = 0.94, P < .01). Low correlations were found between the Sysmex RBC counts and both wet-mount estimates and hemocytometer RBC counts (rho = 0.43, P < .01 and rho = 0.39, P < .01, respectively). Cell preservation in the air-dried sediment preparations was so poor that differential counts could not be performed.<br />Conclusion: WBC and RBC estimates on wet-mount examination agreed with hemocytometer counts and are therefore considered adequate. The Sysmex ST-2000iV/XT did not provide reliable cell counts under the conditions used.<br /> (© 2012 American Society for Veterinary Clinical Pathology.)

Details

Language :
English
ISSN :
1939-165X
Volume :
42
Issue :
1
Database :
MEDLINE
Journal :
Veterinary clinical pathology
Publication Type :
Academic Journal
Accession number :
23205885
Full Text :
https://doi.org/10.1111/vcp.12004