Back to Search
Start Over
Nine-month angiographic and 2-year clinical follow-up of the NOYA biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo native coronary artery lesions: the NOYA I trial.
- Source :
-
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology [EuroIntervention] 2012 Nov 22; Vol. 8 (7), pp. 796-802. - Publication Year :
- 2012
-
Abstract
- Aims: This study sought to evaluate the safety and efficacy of the NOYA stent which is a cobalt chromium-based sirolimus-eluting stent (SES) with DL-polylactide biodegradable polymer (Medfavour Medical, Beijing, China) in treating de novo coronary artery lesions.<br />Methods and Results: The NOYA I trial was designed to compare the NOYA stent with the FIREBIRD2™ stent, a durable polymer SES widely used in China (MicroPort Medical, Shanghai, China); the trial was a non-inferiority trial with a primary angiographic endpoint of the in-stent late lumen loss (LLL) at nine-month follow-up. The secondary endpoints were binary restenosis rates within nine months, major adverse cardiac events (MACE) defined as the composite of cardiac death, myocardial infarction (MI) or target lesion revascularisation (TLR), and definite/probable stent thrombosis (ST) at 24-month follow-up. A total of 300 patients (n=150 in each group) were enrolled in the study from 16 Chinese centres. The LLL in the NOYA group at nine-month follow-up was similar to the FIREBIRD2 group (0.11±0.18 mm vs. 0.14±0.23 mm, p=0.16; non-inferiority p<0.001). The rates of MACE, death, MI and TLR at 24-month follow-up were comparable between these two devices (p>0.05, respectively).<br />Conclusions: The biodegradable polymer NOYA stent was non-inferior to the FIREBIRD2 durable polymer stent with respect to the primary non-inferiority endpoint of in-stent LLL at nine-month follow-up. Clinical outcomes at 24-month follow-up were comparable between the two stents. (ClinicalTrials.gov number, NCT01226355).
- Subjects :
- Aged
Analysis of Variance
Chi-Square Distribution
China
Chromium Alloys
Coronary Artery Disease diagnostic imaging
Coronary Artery Disease mortality
Coronary Restenosis diagnostic imaging
Coronary Restenosis etiology
Female
Humans
Kaplan-Meier Estimate
Male
Middle Aged
Myocardial Infarction diagnostic imaging
Myocardial Infarction etiology
Percutaneous Coronary Intervention adverse effects
Percutaneous Coronary Intervention mortality
Predictive Value of Tests
Prosthesis Design
Single-Blind Method
Time Factors
Treatment Outcome
Absorbable Implants
Cardiovascular Agents administration & dosage
Coronary Angiography
Coronary Artery Disease therapy
Coronary Vessels diagnostic imaging
Drug-Eluting Stents
Percutaneous Coronary Intervention instrumentation
Polyesters
Sirolimus administration & dosage
Subjects
Details
- Language :
- English
- ISSN :
- 1969-6213
- Volume :
- 8
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 23171800
- Full Text :
- https://doi.org/10.4244/EIJV8I7A122