Fugo blade-assisted lens aspiration in a case of intra- and retro-lenticular hemorrhage.
- Source :
-
International ophthalmology [Int Ophthalmol] 2013 Feb; Vol. 33 (1), pp. 5-7. Date of Electronic Publication: 2012 Nov 06. - Publication Year :
- 2013
-
Abstract
- Hemorrhage into the crystalline lens is exceedingly rare but has been described following ocular trauma [1, 2], glaucoma surgery [3-5], laser iridotomy [6], pediatric cataract surgery [7], and also in the absence of an obvious pathology [8]. We describe a case of intra- and retro-lenticular organised bleed which presented 9 years following repair of open globe injury and which was treated using fugo blade-assisted lens aspiration. The fugo blade provided adequate endocoagulation of retrolenticular blood during posterior capsulotomy and prevented undue anterior segment hemorrhage.
- Subjects :
- Adolescent
Eye Hemorrhage diagnosis
Eye Hemorrhage etiology
Eye Injuries, Penetrating complications
Eye Injuries, Penetrating pathology
Humans
Lens Capsule, Crystalline injuries
Lens, Crystalline injuries
Lens, Crystalline surgery
Male
Capsulorhexis instrumentation
Eye Hemorrhage surgery
Eye Injuries, Penetrating surgery
Lens Capsule, Crystalline surgery
Lens, Crystalline blood supply
Subjects
Details
- Language :
- English
- ISSN :
- 1573-2630
- Volume :
- 33
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- International ophthalmology
- Publication Type :
- Report
- Accession number :
- 23129503
- Full Text :
- https://doi.org/10.1007/s10792-012-9663-9