Back to Search Start Over

CIP (cleaning-in-place) stability of AlGaN/GaN pH sensors.

Authors :
Linkohr S
Pletschen W
Schwarz SU
Anzt J
Cimalla V
Ambacher O
Source :
Journal of biotechnology [J Biotechnol] 2013 Feb 20; Vol. 163 (4), pp. 354-61. Date of Electronic Publication: 2012 Aug 30.
Publication Year :
2013

Abstract

The CIP stability of pH sensitive ion-sensitive field-effect transistors based on AlGaN/GaN heterostructures was investigated. For epitaxial AlGaN/GaN films with high structural quality, CIP tests did not degrade the sensor surface and pH sensitivities of 55-58 mV/pH were achieved. Several different passivation schemes based on SiO(x), SiN(x), AlN, and nanocrystalline diamond were compared with special attention given to compatibility to standard microelectronic device technologies as well as biocompatibility of the passivation films. The CIP stability was evaluated with a main focus on the morphological stability. All stacks containing a SiO₂ or an AlN layer were etched by the NaOH solution in the CIP process. Reliable passivations withstanding the NaOH solution were provided by stacks of ICP-CVD grown and sputtered SiN(x) as well as diamond reinforced passivations. Drift levels about 0.001 pH/h and stable sensitivity over several CIP cycles were achieved for optimized sensor structures.<br /> (Copyright © 2012 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4863
Volume :
163
Issue :
4
Database :
MEDLINE
Journal :
Journal of biotechnology
Publication Type :
Academic Journal
Accession number :
22940651
Full Text :
https://doi.org/10.1016/j.jbiotec.2012.08.004