Carotid artery stenting performed with a flow-reversal technique: improved technical performance.
- Source :
-
Journal of neuroradiology = Journal de neuroradiologie [J Neuroradiol] 2013 Mar; Vol. 40 (1), pp. 29-37. Date of Electronic Publication: 2012 Aug 31. - Publication Year :
- 2013
-
Abstract
- Objective: To report our experience in carotid artery stenting (CAS) with GORE flow reversal system, focusing the assessment of its efficacy, security and practice procedure evolution.<br />Methods: Twelve patients treated for atherosclerotic carotid stenosis were prospectively evaluated. All patients were symptomatic. Carotid symptoms were embolic stroke in eight, watershed stroke in two and transient ischemic attack (TIA) in two patients. All patients underwent carotid ultrasound, brain magnetic resonance image and magnetic resonance angiography before CAS procedure. The procedure time and the flow reversal time were registered. Neurological outcome was evaluated before treatment, during the first 48 hours post-treatment and after 3 months.<br />Results: CAS was successful in all cases. Mean procedure time was 33.8 minutes. Mean flow reversal time was 7.3 minutes. Temporary bradycardia occurred with six patients without associated hemodynamic instability. NIHSS patients' scores ranged from 0 to 5 (average 1.1) on admission and remained unchanged during 48 hours after treatment. mRS patients' scores ranged from 0 to 3 (average 1.6) on admission and remained unchanged during the follow-up of 3 months. There were no complications concerning groin puncture, or general anesthesia, or myocardial infarct or death.<br />Conclusion: In our present selected subjects, the CAS procedure using the GORE flow reversal system appeared to be safe and effective, with improved technical performance of the procedure. This was observed in particular with the flow-reversal times achieved. Thus, studies comparing the GORE system and other protection devices are suggested to ascertain all of the benefits of flow reversal during CAS.<br /> (Copyright © 2012 Elsevier Masson SAS. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Equipment Design
Equipment Failure Analysis
Female
Humans
Male
Middle Aged
Prosthesis Implantation instrumentation
Prosthesis Implantation methods
Radiography
Treatment Outcome
Blood Vessel Prosthesis
Carotid Stenosis diagnostic imaging
Carotid Stenosis surgery
Embolic Protection Devices
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 0150-9861
- Volume :
- 40
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of neuroradiology = Journal de neuroradiologie
- Publication Type :
- Academic Journal
- Accession number :
- 22940422
- Full Text :
- https://doi.org/10.1016/j.neurad.2012.03.001