Back to Search
Start Over
Interobserver delineation variation in lung tumour stereotactic body radiotherapy.
- Source :
-
The British journal of radiology [Br J Radiol] 2012 Sep; Vol. 85 (1017), pp. e654-60. - Publication Year :
- 2012
-
Abstract
- Objectives: In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design.<br />Methods: 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SD(trans)) and craniocaudal (CC) direction (SD(cc)) separately. Concordance indexes and volume deviations were also calculated.<br />Results: Median tumour volume was 13.0 cm(3), ranging from 0.3 to 60.4 cm(3). The mean SD(trans) was 0.15 cm (SD 0.08 cm) and the overall mean SD(cc) was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SD(trans) than tumours surrounded by lung tissue.<br />Conclusions: The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours.
- Subjects :
- Aged
Cross-Sectional Studies
Female
Humans
Male
Middle Aged
Observer Variation
Reproducibility of Results
Sensitivity and Specificity
Lung Neoplasms diagnosis
Lung Neoplasms surgery
Multimodal Imaging methods
Positron-Emission Tomography
Radiosurgery
Radiotherapy, Image-Guided methods
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1748-880X
- Volume :
- 85
- Issue :
- 1017
- Database :
- MEDLINE
- Journal :
- The British journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 22919015
- Full Text :
- https://doi.org/10.1259/bjr/76424694