Back to Search Start Over

3-Year clinical outcomes in the randomized SORT OUT III superiority trial comparing zotarolimus- and sirolimus-eluting coronary stents.

Authors :
Maeng M
Tilsted HH
Jensen LO
Kaltoft A
Kelbæk H
Abildgaard U
Villadsen AB
Krusell LR
Ravkilde J
Hansen KN
Christiansen EH
Aarøe J
Jensen JS
Kristensen SD
Bøtker HE
Madsen M
Thayssen P
Sørensen HT
Thuesen L
Lassen JF
Source :
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2012 Aug; Vol. 5 (8), pp. 812-8.
Publication Year :
2012

Abstract

Objectives: This study sought to examine the 3-year clinical outcomes in patients treated with the Endeavor (Medtronic, Santa Rosa, California) zotarolimus-eluting stent (ZES) or the Cypher (Cordis, Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) in routine clinical practice.<br />Background: The long-term clinical outcome in patients treated with ZES in comparison with SES is unclear.<br />Methods: The authors randomized 2,332 patients to ZES (n = 1,162) or SES (n = 1,170) implantation. Endpoints included major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction, or target vessel revascularization; the individual endpoints of MACE; and definite stent thrombosis.<br />Results: At 3-year follow-up, the MACE rate was higher in patients treated with ZES than in patients treated with SES (148 [12.9%] vs. 116 [10.1%]; hazard ratio [HR]: 1.33, 95% confidence interval [CI]: 1.04 to 1.69; p = 0.022). Target vessel revascularization was more frequent in the ZES group compared with the SES group (103 [9.1%] vs. 76 [6.7%]; HR: 1.40, 95% CI: 1.04 to 1.89; p = 0.025), whereas the occurrence of myocardial infarction (3.8% vs. 3.3%) and cardiac death (2.8% vs. 2.8%) did not differ significantly. Although the rate of definite stent thrombosis was similar at 3-year follow-up (1.1% vs. 1.4%), very late (12 to 36 months) definite stent thrombosis occurred in 0 (0%) patients in the ZES group versus 12 (1.1%) patients in the SES group (p = 0.0005).<br />Conclusions: Although the 3-year MACE rate is higher in patients treated with ZES versus SES, our data highlight a late safety problem concerning definite stent thrombosis with the use of SES. This finding underscores the importance of long-term follow-up in head-to-head comparisons of drug-eluting stents. (Randomized Clinical Comparison of the Endeavor and the Cypher Coronary Stents in Non-selected Angina Pectoris Patients [SORT OUT III]; NCT00660478).<br /> (Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1876-7605
Volume :
5
Issue :
8
Database :
MEDLINE
Journal :
JACC. Cardiovascular interventions
Publication Type :
Academic Journal
Accession number :
22917452
Full Text :
https://doi.org/10.1016/j.jcin.2012.04.008